Backflow prevention devices can be installed to replace direct connections. Device selection is based on the degree of cross-connection hazard, as well as piping size, location and other factors.
We've built our business on more than 35 years of personal conversations and problem-solving with our customers. Our team is ready to assist you, so contact us today.
WattsBackflow Preventerforcoffee maker
The Dual Check Valve is a backflow preventer that is used to prevent both back-pressure and back-siphonage. These have two independent check valves and are used for residential supply lines and fire sprinkler systems, post-mix beverage machines as well as tea and coffee machines.
Coffee maker backflow preventerreplacement
Carbonated BeverageBackflow Preventer
In a DCAP, the vent valve is closed during the normal operation and the two check valves open, thereby allowing the flow of water through the unit. In the case of back-siphonage, both the check valves close and the atmospheric vent opens to allow air to enter the intermediate zone. Whereas, in case of back-pressure, if the second check valve does not close tightly for some reason, the leakage is vented to the atmosphere via the vent port. In the case of backpressure condition, the dual check preventer forces the checks to close tighter due to an increase in the pressure. If the second check does not work, the first check acts as a backup to stop backpressure going through the device. In back-siphonage, a sub-atmospheric condition at the inlet causes the loading of the checks so that they close.
Dual check valves do not need any special tools, crimping, glue, or soldering and have a faster install time. The ease of use of these valves reduces the risk of errors produced. They are quite versatile and are compatible with PEX, copper, HDPE, CPVC, etc. pipes. Dual Check with Atmospheric Port is designed for low head loss and has a union for easy maintenance and installation. They are also available with solder connection and pip thread with an internal cone strainer for easy usage. Also, all the parts are temperature resistant making it suitable for both hot and cold water continuous pressure applications. We use backflow preventer devices that meet the requirements laid out by the American Water Works Association (AWWA) Standard for Dual Check Valve(ASSE 1032, ANSI/ASSE 1024)and Dual Check with Atmospheric Port(ASSE 1012)and approved by labs sanctioned by the Conference of State Sanitary Engineers. Smart water backflow services are one of the best water backflow service provider. It offers maintenance, installation as well as repair services to help solve all your backflow problems. You can call us 24x7 for booking our services!
A dual check valve is similar to a double check valve because it consists of two independently acting check valves that are spring-loaded. Both dual check valves and DCAP are used for low hazard applications. However, the dual check valves usually donât include the shutoff valves. The proper selection of backflow preventer is very paramount to ensure adequate protection for the desired application. It is important to remember that different backflow preventers provide different levels of protection.
The Dual Check with Atmospheric Port, or the DCAP, is a backflow preventer that consists of two independently operating check valves that have an intermediate atmospheric port. The DCAPs are designed to protect against both back-siphonage and backpressure. Their applications include sterilizers, underground rainwater tanks, hairdressers, non-toxic boiler feed lines, and laboratory equipment installations. They are mainly used for low hazard applications only.
The Dual Check Valve must be used only for non-health hazard cross-connections and for applications where there is a continuous pressure. It can be installed horizontally or vertically and are compatible with working in tight spaces. The DCAP should be installed according to the accessibility for maintenance and testing of the device. It is highly suggested to maintain a 12ââ minimum clearance between the floor grade and DCAP. It cannot be installed in places where the port-based discharge is questionable.