2-stagepropane regulator forhome

Second Stage Propane Regulators are not used for decreasing tank pressure and, therefore, must be installed downstream of a first stage propane regulator for safe and proper operation. Any regulator seen installed next to a building, most likely are a second stage propane regulator. Second stage propane regulators work with propane at a pressure supplied by the first stage propane regulator (inlet pressure) and further decrease that to a pressure that can be used by appliances (outlet pressure). Most outlet pressures of second stage propane regulators are measured in inches water column, such as 11" water column. This is the standard propane pressure delivered to household appliances so that they can safely and properly operate. Second stage propane regulators are only designed to operate in combination with first stage propane regulators. One cannot work without the other.

Integral Twin Stage Propane Regulators are more commonly used and are more sensible for most installations with a small BTU load inside... BUT in a situation where there is an extreme distance between the tank and house or appliance, a two stage propane regulator system is often the best option. The reason for this has to do with several things including pipe size, total service line distance and appliance BTU demand. A long run (50 ft. and over) from the propane tank to a house with a total load being over 1,000,000 BTU would most likely benefit from a two stage system because an integral twin stage will not supply the propane required that the appliances demand.

Low pressurepropane regulator for house

There's nothing that responds to a little care any better than the LP-Gas regulator. But if it is overlooked, trouble can result. Remember these points:

If you or someone you know needs helping choosing the correct regulator for your application, REMEMBER: You can always reach out to a Tarantin Industries technician.

World class manufacturers of pipeline strainers, check valves, combination valves, suction diffusers , butterfly valves. All styles of strainers including Y type, simplex basket, duplex basket, in all materials and end configurations threaded, socket weld, butt weld, grooved, and flanged. Check valves include wafer double door spring loaded, grooved end double door, wafer center guided, flanged center guided, UL / FM approved valves for fire protection system s and more. Specialty products include combination valves for balance, check, and shutoff of hydronic systems, pump suction diffusers, fabricated strainers, temporary strainers, fire line strainers, turbine meter strainers, and more. Butterfly valves 2” to 36” pipe size, wafer, lug wafer, grooved end, in Cast and Ductile Iron bodies, various elastomeric liners, with Ductile Iron, Aluminum Bronze, Stainless, and Monel discs. Applications for Mueller products are almost endless. Strainer uses include the protection of natural gas and water meters, all process piping where process contamination could be harmful to the pumps, equipment, or the finished product flowing through the piping, straining plant water with units that allow for switching baskets for cleaning without shutting down the process protected. Check valves are designed for prevention of flow reversal in piping systems. All of Mueller’s check valves are of the spring assist design, which allows the valve to close before flow reversal reducing the possibility of hammer in the line. The various configurations of valves allow for selection of the right type valve to meet the specific flow conditions. The wide variety of materials of construction allow for the handling of almost any media. Applications for specialty products allow for the protection and balancing of hydronic heating and cooling systems, fire system piping, startup conditions, and other specialty end configurations and applications in the commercial and industrial markets.

Propane regulator for housestove

Order Online Shop OnlineBall ValvesClearanceConstruction HeaterCylinder and TanksFireplace and HearthFittingsGrills and Outdoor ProductsHeatersHose ReelsHoses and FittingsInternational ProductsMeters and ScalesPipes and FittingsPlant EquipmentPump StationsPumps, Compressors, and MotorsRegulatorsService and Safety EquipmentSigns, Decals, and PaintsTanks and CylindersTop SellersValvesVaporizersVentingWashers and O-RingsBall ValvesIndustrialNeedle ValvesRepair KitsResidentialClearanceAdaptorsCSST PipeGaugesGrillsPipes and FittingsPlastic Pipes and FittingsRegulator AccessoriesValvesConstruction HeaterConvectionForced AirParts and AccessoriesCylinder and TanksCylinder AccessoriesCylindersGaugesShrouds and DomesTank AccessoriesFireplace and HearthAccessoriesBurnersCast Iron StovesFireboxesFireplacesLog SetsMantelsFittingsAll Fittings ItemsGrills and Outdoor ProductsAccessoriesGrillsHeatersOutdoor CookersTorchesHeatersAccessoriesBlue FlameIndustrialInfraredVentedHose ReelsAccessoriesPartsReelsHoses and FittingsFittingsHosesToolsInternational ProductsAccessoriesCylindersRegulatorsValvesMeters and ScalesAccessoriesMetersPartsPipes and FittingsFittingsPipesTools and AccessoriesPlant EquipmentFilling AdaptersFlexible ConnectorsNitrogen SystemsPiping KitsScrubbersStanchionsStrainersSwing CheckTank InverterTank StandsToolsPump StationsAccessoriesCorkenSmithPumps, Compressors, and MotorsBypass ValvesCompressors and AccessoriesMotorsPumpsRepair PartsRegulators2 PSIAccessoriesAdjustableFirst StageHigh PressureRegoSecond StageSingle StageTwin StageService and Safety EquipmentGlovesLeak DetectionSealantsToolsSigns, Decals, and PaintsAccessoriesDecalsPaintSignsTanks and CylindersCylinder AccessoriesCylindersGaugesShrouds and DomesTank AccessoriesTop SellersFittingsPipes and AccessoriesRegulators and AccessoriesValvesAccessoriesAngle ValvesBack Chek ValvesChek LokCylinder and Tank ValvesEmergency Shut Down ValvesExcess Flow ValvesFill ValvesGlobe ValvesInternal ValvesLiquid Level GaugesNeedle ValvesPullaway ValvesQuick Acting ValvesRelief ValvesRepair PartsVapor Equalization ValvesVaporizersDirect FiredElectricWaterbathVentingB-VentsCapsClampsDirect-VentsDrainsElbowsMiscPipesRoof FlashingsTeesWall Pass ThroughsWall ThimblesWashers and O-RingsO-RingsWashers Shop Online

First Stage Propane Regulators LV4403TRSeries 200x200 are installed at the propane tank and connected directly to the service valve with a pigtail. If a first stage propane regulator is used, a second stage propane regulator must be installed downstream. In other words, a first stage propane regulator can't be installed independently in an LP Gas system. There must be a second stage propane regulator installed as well. The first stage propane regulator will compensate for differing tank pressures and will deliver into the gas line at a pressure of 10 pounds or less. The purpose of a first stage propane regulator is to deliver propane at an ample pressure to a downstream second stage propane regulator. That's its only job... to ensure that the second stage propane regulator is supplied with propane at a pressure that it needs to do its job. The REGO variations of first stage propane regulators are numerous and while they are all designed to work with propane tank pressures, the outlet pressures differ by model. First and second stage propane regulators must be properly matched so that the overall gas system is safe and functional. Propane companies work with REGO regulators every day and are able to determine what size and type of first stage propane regulator is needed for the requirements of the installation.

Image