0163725-WATTS: S 40XL-4-150,1.

ParkUSA designed and manufactured a custom DeconTank® for this Washington hospital’s new campus. The state-of-the-art system integrates a fiberglass holding tank, diverter, and control system to manage hazardous wastewater efficiently.

Drawings and specifications. Code, Connection, Note, Cv. 521409A, 1/2" sweat union, -, 3.

Zurn wilkins

Municipal water distribution systems must be protected against potential contamination from cross-connections, such as with industrial or agricultural water sources.

Units prevent the undesirable reversal flow of water or other liquids, gases or substances into potable water distribution pipes.

WattsBackflow preventer

2023731 — We've explored the different types of gas shut off valves, understanding their basic functions, and learning how to choose the right one for your needs.

Our backflow preventor assemblies are manufactured in a variety of models to suit almost any building site. Model types are selected based on degree of potential cross-connection hazard, varying from non-health hazard pollutants to contaminants that could causes illness or death if ingested. Double check valve assemblies are preferred and certified for contemporary use. The double valve adds security and continuously monitors water flow while detecting any abnormal or unauthorized usage. If such usage is detected, it triggers an alarm, notifying personnel or monitoring systems of potential issues.

This 1/2 inch dual check valve backflow preventer with atmospheric vent helps prevent the reverse flow of hot or cold polluted water from entering into the potable water supply. This valve is designed for continuous pressure non-health hazard applications in smaller supply lines, such as laboratory equipment, processing tanks, sterilizers, dairy equipment, and specifically for boiler feed lines. It consists of a brass body with stainless steel internal parts, integral strainer, two durable tight seating rubber check valves, and NPT female inlet and outlet connections.

Residential and commercial buildings need to protect their potable water supply and facilitate a connection to the fire department’s water supply.

Backflow prevention assemblies are often used in fire sprinkler systems to prevent backflow and ensure the integrity of the water supply dedicated to fire protection.

Want to boost your team's knowledge? Need a quick refresher? ParkUSA offers free “Lunch & Learn” presentations to architect and engineering firms, private companies and public-sector agencies. Let us know your area of interest and the appropriate ParkUSA subject matter expert will come to your office, providing lunch, and spend 30 to 45 minutes sharing their knowledge, expertise and experiences with your team. Our Lunch and Learn program is designed to qualify for 1.0 Professional Development Hour for Professional Engineers. Call or email us for more information.

Image

Backflow prevention assemblies are typically equipped with test cocks or ports for periodic testing and maintenance. The check valves can be examined to ensure they are operating properly and closing tightly to prevent backflow.

Image

3/4 Inch 1000mm Premium Gas Hose With Quick-Disconnect Coupling And Straight Restrainer Cable With Mounting Hardware

ParkUSA manufactures multiple backflow preventors for use in various settings including fire department connection assemblies.

backflowpreventer中文

Expansion tanks are required in heating, cooling or air condition system to avoid unacceptable increases of system pressures when water expands during ...

If you wish to receive a physical copy of our Product catalog, please fill out the information below and we will send you one. Please select which catalog you wish to receive.

Check valve

2 Feb 2022 — The 'rule of thumb' calculation is that the pressure vessel size is equal to 6 seconds of maximum flow. For example: if the design maximum flow ...

Backwater valve

Thermostatic mixing valves are used in plumbing and heating systems to control and maintain a consistent water temperature. They combine hot and cold water ...

ParkUSA backflow prevention assemblies protect potable and municipal water supplies by eliminating any potential cross contamination.

Image

An integrated detection feature continuously monitors water flow and can detect abnormal water usage which may indicate an unauthorized tap.

Industrial settings rely on backflow preventers to protect against potential contamination from processes, chemicals, or industrial equipment that could pose a risk to the public water supply.

In spaces with decorative or recreational water features, backflow prevention assemblies are often required to prevent stagnant or chemically treated water from entering the municipal water supply.

The LintTrooper® Model LTDB 2500 helps Portland Rent All enhance wastewater management for their expanding hospitality services. This system ensures compliance with Portland’s pH and solids standards through advanced filtration, pH monitoring, and IoT-based real-time control.

backflowtesting是什么

Backflow assemblies are commonly employed in irrigation systems to prevent the backflow of non-potable water into the main water supply.

A backflow prevention assembly contains all parts within a precast concrete vault. The components vary, depending on model, but the mechanics remain constant. Each assembly has an inlet and outlet. The inlet connects to the source of potentially contaminated water, while the outlet connects to the potable water supply system, usually a building. Water moves from the source through the inlet into the backflow assembly. Check valves are a mechanical device that allows water to flow in one direction while preventing backflow in the opposite direction.

A back pressure regulator is a valve that maintains a defined pressure upstream of its own inlet. When fluid pressure at the inlet of the back pressure ...

Assemblies with one check valve can be used for other non-hazard applications, such as incorporation into fire protection systems.

Two check valve system is the only certified backflow prevention system that provides additional protection against backflow if the first check valve fails or leaks,

Vital to safeguarding potable water supply, backflow assemblies are necessary within hospitals, medical facilities, and laboratories with medical gas and water treatment systems.

Watts 0062025 1/2-Inch NPT 9D-M3 Dual Check Valve with Intermediate Atmospheric Vent, Backflow Preventer. (9DM3-CAN-1/2).

Shape Memory Alloy (SMA) coil allows faster temperature response than conventional wax-type thermostatic valves. For use with many TOTO Thermostatic Mixing ...

Rigorous testing during manufacturing ensures the installation of a working system that meets quality and performance standards.

Backflow prevention assemblies stop the undesirable reversal flow of water or other liquids, gases, or substances into potable water distribution pipes. The assemblies ensure that water flows in only one direction and protects potable water systems from contamination or pollution due to backflow. Each ParkUSA BackFlo® backflow prevention assembly includes a complete cross-connection control solution for all municipal, residential, commercial, and industrial projects. The assemblies are delivered onsite and ready to plumb.

Certified backflow prevention systems contain a double check valve assembly. Check valves are mechanical, spring-loaded, or pressure sensing devices that close when there is a reversal of water flow. Under normal operation, the check valves remain open allowing water to flow without restriction. If there is a reversal in water flow and a potential of backflow, the check valve will close due. This initial closure blocks the reverse flow of water. A single check valve unit is not a certified backflow prevention system, and now rarely used to ensure cross-connection quality.

3/4 Nidel Integral · 1/2 ANTI-SIPHON LF VAC BREAKER (CP) · 1/2 ANTI-SIPHON LF VAC BREAKER (RB) · 3/8 M X F LF LAB FAUCET VAC BREAKER · WATERSAVER V/B GASKET · 1/2 LF ...