Guardian Enclosures Extra-Small Steel Backflow Australia - backflow preventer box
TekmarRadiant Thermostat
The email you entered is already subscribed. You can customize your email settings from the personal account setting page or click on the Customize Emails button below.
This drawing for a PDI G101/ASME Type A grease interceptor appears to be compliant with the IPC, as stated above. Assuming the interceptor is intended to serve as a fixture trap, there is no requirement to install an additional trap and vent between the fixture and the interceptor.
Watts WiFi Thermostat
PDI G101 and ASME A112.14.3 Type A certified interceptors are required to have a vented external flow control installed upstream of the interceptor.
Breeze33 offers high quality HVAC and air distribution products that are priced right. From mini split systems to room air conditioners and dehumidifiers and registers, you can count on Breeze33 for convenience, quality and value.
To be honest, much of the confusion around code compliant installations can be the result of boilerplate drawings provided by manufacturers in submittals or installation instructions. Manufacturer's want to provide guidance for a broad range of installations without providing detailed drawings for every single installation variable that can exist. When it comes to traps and vents for grease interceptors and the fixtures discharging to them, it's incumbent upon an engineer or contractor to identify and comply with local code requirements regardless what a manufacturer's drawing shows.
That being the case, the interceptor does not require a vented external flow control - jurisdictions unfamiliar with this type of interceptor often question drawings like this and understandably so.
Figure 2.Actually, nothing!The drawing shows a PDI G101/ASME Type A grease interceptor connected to a three compartment sink that is trapped and vented, an external flow control with air intake and a vent on the downstream side of the grease interceptor. This installation would be compliant with both the IPC and the UPC.
Famous Supply has over 45,000 products in stock with experts to serve the residential, commercial, institutional & industrial markets.
Tekmar563 Thermostat Manual
The unit shown is certified to ASME A112.14.3 Type C with a built-in or integral flow control and does not require an air intake.
Find solutions tailored to meet your professional plumbing, HVAC, and building company needs. We offer a wide range of programs and services to help customers streamline daily operations. See what Famous Supply can do for you.
TekmarBoiler Control
What's important to remember about AAVs is that they only allow for the relief of negative pressure in the drainage system. Therefore, when using an AAV to vent a grease interceptor, it's important that the drainage system has provision for the relief of positive pressure to ensure proper flow.
Honeywell thermostat
With 31 Famous Supply locations in Ohio, western Pennsylvania, and West Virginia, your local Famous counter has everything you need to help you get your project done. Famous’ greatest asset is our quality Associates dedicated to serving you!
tel: (913) 951-3300 | fax: (913) 951-3399 | 6455 Woodland Drive | Shawnee, KS 66218
Model plumbing codes require each fixture discharging into a grease interceptor be individually trapped and vented, and require the installation of a vent downstream from the grease interceptor. Standards also come into play when determining the type and location of vents upstream from a grease interceptor.A plumbing line upstream of grease interceptor.PDI G101 mandates the installation of a vented external flow control. The vent on the flow control is an air intake. As the waste stream flows through the orifice in the flow control device, negative pressure is created. This pressure draws in air from the air intake, which is intended to mix with the waste water as it enters the grease interceptor to aid in separation efficiency.
Bright33 offers high quality LED lighting products priced right. Discover indoor and outdoor LED lighting options from undercabinet to ceiling and vanity, you can trust Bright33 for convenience, quality and value.
Tekmar557 Manual
With 45,000+ SKUs, Famous Supply specializes in HVAC, plumbing, industrial, building products, and training. We sell into the residential, commercial and industrial market segments for new construction, replacement, repair, remodel, parts and service.
Craft33 offers high quality all-wood cabinetry that is priced right. Styles from transitional to modern and traditional, you can count on Craft33 cabinets to compliment your clients’ lifestyle and budget.
Ecobee thermostat
Schier is a privately-owned manufacturer of a premier lineup of 100% USA-made, high-capacity, lifetime guaranteed grease interceptors for commercial kitchens. In the last 20 years we have grown from a small regional company to the most widely specified brand of grease interceptors in the U.S. Our purpose is to serve and provide for our employees by being a resilient company that offers best-in-class products and services.
For compliance with the UPC this drawing would have to show both a vented external flow control and a trap and vent for the fixture.
Stream33 offers high quality plumbing products priced right. From bathroom and kitchen products to pre-assembled installation kits and behind-the-wall products, you can count on Stream33 for convenience, quality and value.
Famous can help you with specifications, product options, design, layout, and coordination of your project from A to Z. We are your one-stop shop for HVAC, plumbing, cabinets, countertops, appliances, lighting, windows and doors.
It depends on which model plumbing code applies to the installation. The International Plumbing Code (IPC) 1002.1 (exception 3) allows a grease interceptor to serve as a fixture trap - where it is intended by the manufacturer to serve as a trap - for a single fixture or a combination sink of no more than three compartments. The vertical distance from the outlet of the fixture to the inlet of the interceptor must not exceed 30 inches, and the developed length of the waste pipe from the most upstream fixture outlet to the inlet of the interceptor must not exceed 60 inches.
Tekmar561 Amazon
Setbacks are a thing of the past with our many delivery solutions. Famous Supply will deliver your order how, where, and when you need it. You can even track the status of your order in a few clicks with a Famous-Supply.com account.
The Uniform Plumbing Code (UPC) does not permit a grease interceptor to serve as a fixture trap and also prohibits the installation of a vent between the air intake on the flow control and the grease interceptor. The above diagram would not be compliant with the UPC. There needs to be a trap and vent between the fixture and the vented flow control fitting.
Figure 3.The drawing shows a PDI G101/ASME Type A grease interceptor with an external flow control with air intake, however, it also shows a trap on the fixture but no vent for the trap. This is not compliant with the IPC since the code does not allow double trapped fixtures. The code does allow the interceptor to serve as a trap (assuming that this interceptor is intended to serve as a fixture trap), thus adding a trap to the fixture upstream of the interceptor creates a double trapped fixture installation. Either adding a vent to the trap or removing the trap on the fixture altogether would solve the problem.The only solution for compliance with the UPC is to add a vent for the trap on the fixture upstream of the vented flow control fitting.
The UPC does not include provisions for AAVs except as a part of an "Engineered Vent System" under section 912.0, much to the chagrin of engineers around the country. Many states that adopt or adapt the UPC have added an allowance for AAVs, so you will have to check with your state to see if they are approved.
This installation is compliant with both the IPC and the UPC since it shows a trapped and vented fixture discharging through an approved interceptor without external vented flow control with a vent installed downstream.
Since all semi-automatic draw-off grease interceptors are certified to either PDI G101 or ASME A112.14.3 Type A, an external vented flow control must be shown for compliance with the IPC.
A portion of every Stream33, Breeze33, Craft33, and Bright33, purchase will be donated to your local Feeding America foodbank. Famous Supply will also make product donations to Habitat for Humanity. All to help make our dream of better local communities become a reality.