I have a 1” Febco 765 that I think has been damaged from freezing over the winter. Is it worth trying to repair this assembly or should I just replace it with a new one?  Can you give me some information on repairing this unit?

This 3/4 inch Y pattern reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of high hazard (toxic) fluids found in the ...

We continues to enhance our visibility and reputation, including exhibitions all over the world and we also actively taking corporate social responsibility.

is removed. BASIC REPAIR KIT. The replacement kit for the 1/2"-1 1/4" contains bonnet assembly, ...

Lf009m3qtParts

Image

Image

Wattslf009m3qtleaking

MAG-BEECO Backflow Preventers are easy valves to access and service. They deliver the highest level of performance and reliability and will deliver savings on maintenance and commissioning costs.

CL500 ONLINE CHLORINE ANALYZERS Online residual chlorine monitors for most on-line chlorine monitoring applications. FEATURES: Proven colorimetric DPD ...

LF009M2QT

Series PLT Potable Water Expansion Tanks are designed to absorb the increased volume of water created by thermal expansion and to maintain balanced pressure ...

Zurn's water pressure regulator valve is ideal for residential & commercial applications. Check out our complete line of pressure vacuum breaker.

The bonnet and poppet in this assembly are made of plastic and will usually be the parts that break first when the unit freezes. To replace these components we will first have to remove the canopy. The canopy will be a metal, bell-shaped protective cover on top of the unit. It is secured to the bonnet with a lock nut. The bonnet assembly is threaded into the brass body and is sealed with an o-ring. The bonnet will unscrew counterclockwise. If you need a wrench to help loosen, be sure to place the wrench on the very outside diameter of the bonnet to avoid any further damage.

lf009m3-qt-fs 3/4

Once you remove the bonnet assembly for the 1″ Febco 765, you can get to the poppet assembly. The poppet simply floats up and down within the body and is guided by a stem on the bonnet. The poppet is not attached to anything and comes right out. The next component you will need to inspect is the check assembly. The check assembly is spring-loaded. The check poppet and check spring are held into place by a retainer. The retainer is a flat metal bracket that locks into the brass body. To remove the retainer, simply push it down and turn it 90 degrees. Once that is removed, the spring and the check will come right out.

The entire valve can be fully serviced inline, fewer parts are needed and ease of valve access and servicing means real savings of time and money.

The check assembly can be damaged from freezing, but normally it is intact and still works fine, but it is always a good idea to check it as well. Another thing to look out for when an assembly freezes are the inlet and outlet shutoff valves. Be sure to check those for leaks and replace as needed. Always keep in mind that an ounce of prevention is worth a pound of cure. If the assembly is properly protected with some type of freeze protection or, if possible, removed from line and stored for the winter, then the spring repair and maintenance bill will be a little lower.

It is that time of year again. As spring arrives, people are starting up those irrigation systems and getting them ready for the upcoming season. Usually, the first thing that needs repair in the system is the backflow preventer that was not drained or removed for the winter and was exposed to freezing temperatures. The question of whether to repair or replace is very common when you are watching the geyser coming from the backflow preventer. As a rule of thumb, unless there is a crack in the body of the assembly, you can normally repair without a lot of hassle or expense. Let’s take a look at how to repair this assembly and what components typically can get damaged from freezing.

Lf009m3qtRepair Kit

For hot and cold water, configured in S/Steel cabinets with either clear viewing Perspex front panel or optional S/Steel

watts lf009 3"

See our range of Reduced Pressure Zone Devices (RPZDs) for High Hazard applications, Double Check Valves (DCVs) for Medium Hazard applications, purpose built Australian-made In Wall Backflow Tundish cabinets and Detector Check Valves (single detector and double detector) for fire applications.

• Maximum protection in Low Hazard conditions (Single Detector Check Valve) and in Medium Hazard conditions (Double Detector Check Valve) in fire sprinkler systems

Watts LF009 spec Sheet

For hot and cold water, configured in S/Steel cabinets with either clear viewing Perspex front panel or optional S/Steel

Browse Dielectric Unions in the Mueller Industries Inc. catalog including Mueller Streamline PRS™ Dielectric Union (PxFPT)

Image

Watts 88004111

Severn Trent Water · Hafren Dyfrdwy · Severn Trent Services · Severn Trent Green Power · Severn Trent Connect. © Severn Trent Water 2016 - 2024. Click to toggle.

12 in. Wide Trench Frame & Grating -- Dead Level ® DX-GF from Watts. Watts Dead Level DX-GF 12 in(305mm) wide x 48 in(1219mm) long (standard) ductile iron ...

rating; and for compliance with any appli- cable water heater labeling requirements: Use 1" and over T&P valves tested under. ANSI Z21.22 with ratings as ...

We're upgrading Controls Central to improve your experience! In addition to accessing the best pricing, here's what you can expect: Expanded Content: Access more resources to help you select the right products. New Products & Data: We add product images and information daily, making it easier to find what you need quickly. Easier Returns: Enjoy more time for returns with no restocking fees on returns up to 90 days. And as Always Exceptional Service: You can count on our friendly customer service and tech support. Plus, benefit from fast shipping and an easy credit process. Our prices are so competitive they're too good to display publicly. Log in to see the savings! Experience these new benefits and discover why we're recognized as one of the leading HVACR MRO parts resellers! From all of us at Controls Central, Thank you for your business! Login and Start Saving!

The grooved end check valves are UL/ FM approved. It is suitable for use in building riser pipes and sprinkler systems for fire protection. The grooved ends feature a time saving installation and the built-in spring ensures a smooth and non-slam closure of the dual plate discs.

You may have temporary loss of water pressure. An RO system needs a minimum of 40 psi to operate properly, but preferably 60 psi. If all your household faucets ...