2018 International Plumbing Code (IPC) Section 608.17.1.2, Coffee makers and non-carbonated drink dispensers, says: “the water supply connection to each coffee machine and each non-carbonated beverage dispenser shall be protected against backflow by a backflow preventer conforming to ASSE 1022 or ASSE 1024, or protected by an air gap.”
The Series PB410 HydroGuard® features heavy, cast brass construction a poppet-type equalizing valve as part of a replaceable cartridge.
Es150m
800M4 ... The Watts 800M4 is a pressure vacuum breaker (PVB). It is available in 1/2″-2″ sizes and has been in production since 1994. The body is made of bronze.
An ASSE 1022 device has a vent opening that leaks water when the downstream check valve of the device fails. The leaking water is required to drain indirectly to a safe point of discharge.
Fabricated Y Strainers remove sand, dirt, pipe scale, grit, welding beads and other unwanted solids from industrial liquids, gases, water, and steam.
The IPC also allows dual check valves conforming to ASSE 1024, which do not have a vent and subsequent drain. A double check valve could also be protective against Legionella, especially if the supply to the coffee maker is a line that tees off from the supply to an ice machine.
Lockwood electric strike
ES150electric strike
RK009M2-T Watts Total Repair Kit For 1" 009 Reduced Pressure Zone Valve.
Run-Off tubes connect to the temperature and pressure relieve valve (T&P valve) to direct any water released away from the water heater and into a drain. Sort ...
The first and primary responsibility of designers and engineers is to protect the public’s health, safety, and welfare, so when in doubt, provide backflow protection.
957-NRS Stainless Steel Reduced Pressure Zone Assembly with Non-Rising Stem Resilient Seated Gate Valve, 2-1/2 in, Flanged, 175 psi, Lead-Free
ES150 offers high levels of security and features usually provided by more expensive electric locking solutions. The electric strike can be easily installed on steel and wooden door frames. A Weather resistant version is also available for exterior applications.
The purpose of a backflow preventer is to prevent cross-contamination between the potable system and any other source of liquid that might contain a contaminate. These contaminates could be a nascence, a low hazard, or a serious hazard. While coffee is not considered a hazard in a potable water system, it does not belong there. Additionally, coffee pots occasionally get chemically cleaned, which could be a serious hazard if those chemicals were to enter the potable system.
LockwoodES150manual
It works as a mixing tool, as it combines both cold and hot water to correctly produce the required water temperature to be released from a particular outlet.
ASSE 1022 backflow preventers are specially designed for carbon dioxide exposure. They are acceptable for use with carbonated drink dispensers, non-carbonated drink dispensers, and coffee machines. However, coffee machines and non-carbonated beverage dispensers can be connected to the potable water supply using ASSE 1024 backflow preventers, as introduced in the 2018 IPC.
BK Products supplies dielectric unions to the wholesale distribution channel for residential & commercial jobs and several other adjacent categories, ...
Markham Jarrett, a Plumbing Designer with Spectrum Design in Martinsville, Virginia, recently wondered if a coffee maker would have to follow the same code requirements as other beverage-dispensing machines, so he asked our experts on ASPE Connect: Does a coffee maker require a backflow preventer, vent, and drain for commercial jobs?
WATTS® Under Sink Guardian® Thermostatic Mixing Valve, Series: USG, 3/8 in Nominal, Compression, 150 psi, 80 to 120 deg F, 0.25 gpm Flow, Media: Hot/Cold ...