The boiler's high-temperature limits must be, at most, the max temperature rating of parts of the systems. This will protect the component from temperature failure when sediment, dirt, or other mechanical issues cause the mixing valve to be inoperable.

Product(s) in your cart may not be available in the selected country and will be removed from your cart if you choose the “SELECT” button below. Please contact us if you need assistance purchasing this product in another country.

Product(s) in your cart may not be available in the selected country and will be removed from your cart if you choose the “SELECT” button below. Please contact us if you need assistance purchasing this product in another country.

The Fisher 627BM is the newest product extension to the 627-product family. The balanced trim design enables this pressure regulator to achieve a 1,500psig inlet pressure rating while using a large 9/16” orifice. With a flow rate capability that is five times the traditional 627, the 627BM can displace oversized pilot-operated regulators and parallel runs of direct-operated regulators.

Pilot-operated regulators are a two-part system with a pilot and a main valve. The pilot ( the brains) provides a small change to the main valve ( the brawn) opening or closing the main valve depending on the downstream pressure.  Pilot-operated regulators provide larger flow rates and greater accuracy capabilities to users.

Each year around 20 people get into fatal accidents due to scalding from hot water just in the UK. Around 570 people suffer from injuries. But many o these injuries can prevent by using Thermostatic Mixing Valves. The majority of many occupied buildings in the UK are served to have hot water storage and distribution systems. With the usage of safety products, such injuries can be avoided.

This session covers an overview of the sizing and selection of regulators, considerations, details to look out for when selecting self-operated and pilot-operated regulators, and resources for more information.

Emerson is the global technology, software and engineering powerhouse driving innovation that makes the world healthier, safer, smarter and more sustainable.

The Fisher 627BM is the newest product extension to the 627-product family. The balanced trim design enables this pressure regulator to achieve a 1,500psig inlet pressure rating while using a large 9/16” orifice. With a flow rate capability that is five times the traditional 627, the 627BM can displace oversized pilot-operated regulators and parallel runs of direct-operated regulators.

By selecting a new country/region, product(s) may be unavailable and items in your shopping cart will be removed. Please contact us for assistance.

Includes pressure regulators, slam-shuts for pressure protection, relief valves, odorant injection systems, and accessories such as filters and heaters.

Fisher™ LP-Gas regulators are the propane industry standard for reliable pressure regulation across a range of stationary storage and mobile applications.

Most TMVs use the wax thermal for proper regulation. They also help shut off rapidly in case of a hot or cold supply failure, preventing scalding or a thermal shock. It is now a common practice around the globe to regulate storage water temperature to over 60 degrees C.

Tell us how we can help. Our team of pressure regulator experts is here to provide technical support and advice, pricing and billing assistance, and answer general inquiries.

This platform for pressure regulators brings field-proven, modular designs that provide True-Monitor, slam-shut, and secondary seat protection.

The hot water mixing valve is easily adjusted by 2-inlet mixing, by which water temperature is moderated by mixing cold and hot water. The tempering valve aims at getting a temperature of 50 degrees. Upon the failure of this valve, the water temperature doesn't get right. If the TMV valve works correctly, you might notice that the hot water starts running hotter than it must if this valve isn't able to regulate temperature ideally. It may need help to cool down hot water to make it safe.

Sanitary regulators are engineers for pressure control in sanitary of "clean" environments for pharmaceutical, biotechnology, food and beverage, cosmetics, chemical and other industries.

Safe storage and domestic hot water distribution are applicable in all applications. There is a complete line of thermostatic valves to make sure safe tempered water is delivered from a source to use.

Any substance that is capable of flowing or of being poured is known as a liquid. Most common is water but other liquids include detergents, paints, aqueous chemicals, fuels and oil.

Steam is generated & distributed at much higher pressures & temperatures than are required by the process load. Pressure-reducing regulators are used in application to reduce the steam pressure to a usable level & to accurately maintain process fluid temperatures.

The mixing valve is a mechanical device mixes cold with hot water to perfectly deliver tempered, mixed, or water downstream. These devices may be put directly to the water heater outlet so that this tempered water gets delivered around.

High-pressure transmission pipelines move the gas from the production company’s cleaning plants to gas distribution companies for sale to consumers. Regulators & control valves control the high-pressure gas as it moves along the pipeline. At city gate stations & farm taps, regulators reduce the pipeline gas pressure to distribution pressure.

The first in our series of basic regulator operation sessions, this webinar defines the purpose of a self-operated regulator and explains the principle of operation.

The thermostatic mixing valve is the valve that blends hot water with cold water to make sure a constant and safe shower outlet temperature prevents scalding. The storage of this water at high temperatures removes any possible breeding ground for legionella, which is using a thermostat instead of the static mixing valve, giving increased safety against scalding and increased user comfort, just because the hot water temperature always stays constant.

Fuel gas, either natural gas (methane) or LP-Gas, is the typical energy source for a variety of plant utility and industrial applications requiring heat such as boilers, dryers, evaporators, hot water heaters, plant heating systems, industrial ovens and heat exchangers.

The Fisher™ product portfolio offers fit-for-purpose tank blanketing regulators that can help mitigate risks associated with normal & unexpected pressure changes in storage tanks & help reduce blanketing costs.

We move on to pilot-operated regulators in this session. This webinar discusses the principle of operation and comparison with self-operated regulators.

Pressure reducing regulators, also known as pressure reducing valves, are mechanical devices which achieve automated pressure control without an external power source. Pressure reducing regulators reduce a high, often variable upstream pressure to a lower steady outlet pressure despite varying flow demand from the equipment it is supplying. To match this demand, the pressure reducing regulator valve throttles, allowing more flow when demand increases and choking off the flow when demand decreases.

Image

Robust and reliable  self-contained pressure reducing regulators, setting industry standards and driving operational excellence.

Gases are used in chemical and industrial processes such as analytical instrumentation, environmental compliance, electronic manufacturing, chemical production, reference gases, and medical uses.

Plant air or shop air runs from the compressor throughout the plant. Pressure reducing regulators control the pressure to devices at each point of use off the air line.

TMVs are important for delivering eth hot water safely. They remade to shut down in the event of a cold water supply failure to prevent the release of scalding hot water. And they may also shut down if there is a hot water supply shortage to report the potential of a thermal shock.

TMV stands for the thermostatic mixer valve, a fitting installed to control the water temperature from the showerhead or tap. It is an important piece of pipework that prevents users from getting scolded. In all buildings, mainly in huge locations such as schools and hospitals, it isn't easy to ensure that the same temperature of the water is coming from the taps at one end of the priority compared to the other. Hence TMV valve is installed, which regulates the flow of water to make it at a safe temperature at the site.

What is a pressure regulator for? What does a pressure regulator do? On a very basic level, regulators provide a way to control the pressure of gas or other fluids to downstream processes or customers. Self-operated regulators work to meet or fulfill downstream demand while keeping downstream pressure constant.