Watts 800 PVB

More than just hydration, RIVIVE is a statement of intentional engineering design for the convenience of end-users, facility managers, specifiers, and installers.

Watts Backflow Preventer - LF009M2QT / LF009M2-QT-FS Lead Free Reduced Pressure Zone Assembly 0391004 / 88004112 - 1 INCH

2012221 — BACKFLOW PREVENTION ASSEMBLY INSTALLATION GUIDE. DOUBLE CHECK VALVE ASSEMBLY (DCVA). (3/4 – 2) Below Ground Installation. This insert serves ...

Watts Vacuum Breaker Repair Kit

Image

watts vacuum breaker 3/4

Want to install reliable radiant heating system at your house? Heat-On offers reliable system at low radiant heating system cost.

Order Watts Backflow Preventer Repair Kit, LFRK 909-RT 6 at Zoro.com. Great prices & free shipping on orders over $50 when you sign in or sign up for an ...

Register to receive the Haws E-Newsletter, featuring Haws plumbing and safety product news, helpful articles and upcoming events.

The ultimate in emergency response! A Free-Standing Stainless Steel Emergency Shower Certified by CSA to meet the ANSI Z358.1 standards.

Description · RPZ for high-hazard installations · First and second checks are accessible for maintenance without removing relief valve or entire unit from the ...

Watts Pressure Vacuum Breaker

Watts LF800M4QT

Model 9201EFE (patent pending) is a thermostatic mixing valve that mixes hot and cold water to supply tempered water of up to 12 gpm (45.4 L) for emergency eyewash fixtures. Unit employs a paraffin filled thermostatic mixing element. Lowest internal pressure drop where supply pressure is low, and a high Cold Water Bypass flow rate of 10 gpm (37.8 L). The improved brass design with a one piece casting uses internal check stops, over-sized valve seats, a shuttle design that eliminates valve binding, and a funnel design to improve temperature control with better mixing at low flow rates. Lime and calcium resistant components are used throughout. The outlet temperature factory setting is 85° F (29° C). Maximum operating pressure: 125 psi (8.62 Bar). Temperature adjustment range 60 - 90° F (16 - 35° C). Min/max inlet hot water temperature: 120°/180° F (49°/82° C), with recommended inlet temperature: 140° F (60° C). Min/max inlet cold water temperature: 40°/70° (4.4°/21.1° C). Inlet 1/2" NPT(F). Outlet 3/4" NPT(F).

Thermostatic Mixing Valves · Thermostatic Mixing Valves · Design · Case Studies · Specification. Lead-Free Valves · CSI 3-Part Spec Guideline Section 221119 ...

Image

Model 9201EFE Emergency Thermostatic Mixing Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied - ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.) A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range AXION's superior design and technology provide a complete safety solution for increased victim comfort. Lowest internal pressure drop for this class of valve (advantage where supply pressure is low) Wax based thermostat technology for fast response time with proven highly reliable temperature control Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate) Brass valve design with internal check stops Over-sized valve seats resist failures caused by foreign matter A new and efficient shuttle design eliminates Thermostatic Mixing Valve sticking A custom funnel design improves temperature control at low flow rates Outlet temperature is factory set to 85° F (29° C). Tempered water: High temperature limit is factory set to 90° F (32° C). Cold water by-pass valves are closed during normal operation, regardless of flow rate. For important installation information, please read Scald Warning. CSA Listings: CSA certified per ASSE 1071, ANSI/ISEA Z358.1 and applicable sections of CSA B125.3.

watts 3/4 vacuum breaker repair kit

Image

The Iowa State Plumbing Code requires cities with a population of 15,000 or greater to enact a backflow prevention program with a containment system. The ...

Pressure & Safety Relief Valve - Pressure Relief - BSPT - Brass (35). Pressure & Safety Relief Valve - Pressure Relief - BSPT - Copper (1).

Watts800M4repair Kit

Watts® LF009 Series Backflow Preventer is engineered to stop contaminated water from flowing back into the clean water supply due to backsiphonage or back ...

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.

Model 9201EFE AXION® Emergency Tempering Valve thermostatically mixes hot and cold water to provide a safe fluid supply for a single emergency eye/face wash, with a flow rate of 12 gpm (38.8 L).

Prop 65 Warning. For California Residents Warning: This product contains a chemical known to the State of California to cause cancer and/or birth defects or other reproductive harm. Please click here for more information.

May we use cookies to track your activities? We take your privacy very seriously. Please see our privacy policy for details and any questions.

Thermostatic mixing valves function by utilising a thermostatic element that reacts to temperature changes in the incoming water supply. They blend hot and cold ...