Keep your heating system running smoothly with a replacement Watts M335-M2 PRV 30 PSI. At Parts4Heaing we keep Watts pressure relief valves in stock and ...

shut off valve - bunnings

Of concern here is not only this, but if someone did that with your hot water heater, could they have plumbed the propane into your entire house? If so, there is significant risk of that excess heat causing damage to the fire box of your heater, which can then lead to gasses like carbon monoxide getting into your living space and poisoning you! There have been news reports of whole families being killed as a result of substituting propane for natural gas to heat their homes (without making the necessary changes).

From memory the propane orifice would be larger so by using the natural gas your heater would not get as hot as it would with the correct orifice so I do not think it would hurt anything.

Nat gas orifice is significantly larger than propane orifice , so the heaters have been exposed to more heat /flame than design ; that could be a problem. I learned this the hard way; hooked up a nat gas grill to a propane bottle. On the lowest burner setting flame came out around the space between the top and bottom of the grill. In round numbers the gas molecules take up the same volume ( Ideal gas law) . In the nat gas molecule you have one C and 4 H to burn , in a propane molecule you have three C and eight H to burn. So the nat gas orifice is larger to let more molecules through , it lets the same larger number of propane molecules through producing more heat/flame.

Types ofshutoff valves

Added : Orifice size for natural gas range from # 54-31 (drill bit sizes) Propane orifices range #62-48 so I had it backwards The larger the number the smaller the hole. In this case there was two much going to the heater so it may have shortened the systems life , however since the air mixture was probably off it may not have been burning efficiently and wasting gas.

Standard Capacity Pressure Reducing Valve, 1 in Nominal, FNPT Union x FNPT End Style, 25 to 75 psi Pressure, Copper Silicon Alloy Body, Domestic

Stainless steel floor drains from AWI are created with a sanitary design for food processing & the dairy industry. Learn about our USDA approved drains.

Watershutoff valves

Watts® Pressure Reducing Valve, Series: LF25AUB, 3/4 in Nominal, FNPT Union x FNPT, 25 to 75 psi, 33 to 160 deg F, Media: Water, 5-5/16 in Inlet to Outlet ...

Question...Over the past 18 months, after our home was built, we learned our two tankless water heaters have been running propane through a natural gas orifice. We discovered the issue after hearing a loud noise coming from one of the water heaters. Could this have damaged the water heaters? Thanks in advance

Trench Drains are the perfect solution for your surface drainage problems. They collect surface water run-off and prevent safety hazards. Our skilled plumbers ...

SharkBite water hammer arrestors are essential to protect plumbing systems against damages caused by water hammer. View now.

What is a shut off valve in Plumbing

Shutoff valvesreplacement

Reminder: Answers generated by artificial intelligence tools are not allowed on Home Improvement Stack Exchange. Learn more

20221021 — The temperature sensor would close the recirculation and the back pressure on the pump would shut it off until the temperature dropped.

Watts 3/8" LFN9C Chrome Dual Check W/Atmospheric Vent Back Flow Preventer ; Brand. Watts ; MPN. LFN9C ; Accurate description. 4.8 ; Reasonable shipping cost. 5.0.

The basic means of preventing backflow is an air gap, which either ... The basic mechanism for preventing backflow is a mechanical backflow preventer, which ...

Shutoff valvessizes

© Plumbing Distributors, INC. | 242 S. Culver St. Lawrenceville, GA 30046 | All Rights Reserved | eCommerce platform by Unilog.

Our dirt & air separator solutions can help to prevent this and achieve optimum operating conditions. Duraflex separation technology uses mechanical ...

An appliance designed for natural gas has the burner orifices (flame holes) designed for the pressure and flame temperature of a natural gas system. Propane burns with twice the energy of natural gas, so if you put propane through a burner designed for the lower pressure / lower yield gas, it will burn significantly hotter and potentially more dangerously. It will also likely waste a lot of heat because the heat exchanger in the water heater was designed for a specific amount of flame contact. So the hotter / larger flame coming from the propane will just go up the flue as waste heat. It MIGHT possibly cause damage to the heat exchanger, only the water heater mfr could tell you for sure, but it's a sure thing they will not tell you that it is OK.