Series 909RPDA Reduced Pressure Detector Assembly Backflow Preventers are designed to prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 909RPDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of a coated cast iron body using ArmorTek™ coating technology for advanced corrosion resistance, body with stainless steel trim, bronze gate valves, a pressure-differential relief valve, shutoff valves, and bronze ball-type test cocks. Series 909RPDA provides maximum flow at low pressure drop utilizing the air-in/water-out design principle for protection during emergency combined backsiphonage and backpressure conditions. Maximum Working Pressure: 175psi (12.06 bar). The coating on this backflow assembly uses ArmorTek™ technology to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate. Features: Replaceable bronze seats, Modular design facilitates easy maintenance and assembly, Unique two-channel relief valve provides maximum capacity during emergency conditions and stops potential backflow using air-in/water-out principle, Provide detection point for costly water leaks and illegal taps, The valve body shall utilize a coating system with built in electrochemical corrosion inhibitor and microbial inhibitor.

Rpdadisease

100 GPD Reverse Osmosis Membrane Industry's most reliable method of water filtration for home drinking water Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 100 GPD at 60 PSI We suggest changing your membrane every 2 years. Specifications 100 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-100 & 2012-100 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity

50 GPD Reverse Osmosis Membrane Elements for Home Drinking Water Industry's most reliable method of water filtration Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 50 GPD at 60 PSI We recommend changing your membrane every 2 years. Specifications 50 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-50 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity

CoreLogic property value

We're improving the website for a better experience.Some labels for systems and filters might not match the images upon receiving your order during this transition.

Pressure Relief Valve Boiler(218) · Gerich Safety Valve Pressure relief valve Boiler 1/2inch Threads Brass Adjustable · 0.75 in. · Watts 3 4 Iron Boiler ...

Watts 9D-M3 1/2″ Female NPT Dual Check Backflow Preventer. $96.85. Watts 9D-M3 1/2″ Female NPT Dual Check Backflow Preventer with Intermediate Atmospheric Vent ...

CoreLogic house prices

2024524 — 8 likes, 2 comments - midamericamktg on May 24, 2024: "The Dead Level Trench Drain is uniquely designed to install and perform like no other ...

Safe Drinking Water Act: This product contains leaded bronze and is not intended for applications anticipated for human consumption. More Information

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

50 GPD Reverse Osmosis Membrane Elements for Home Drinking Water Industry's most reliable method of water filtration Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 50 GPD at 60 PSI We recommend changing your membrane every 2 years. Specifications 50 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-50 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity

RPDAmedical abbreviation

100 GPD Reverse Osmosis Membrane Industry's most reliable method of water filtration for home drinking water Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 100 GPD at 60 PSI We suggest changing your membrane every 2 years. Specifications 100 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-100 & 2012-100 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity

2022126 — Oil-water separators utilize a coalescing principle or centrifugal design to remove condensate from an air compressor. The airflow in coalescing ...

RPDABackflow

100 GPD Reverse Osmosis Membrane Industry's most reliable method of water filtration for home drinking water Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 100 GPD at 60 PSI We suggest changing your membrane every 2 years. Specifications 100 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-100 & 2012-100 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity

GLWA is looking for highly talented, well-qualified individuals to help us fulfill our vision to be the water and wastewater service provider of choice in ...

Swing Check Valve Brass 15mm · Vacuum Breaker 25mm · Vacuum Breaker 20mm · Dual Check 25mm Brass Backflow Device · Dual Check 20mm Brass Backflow Device · Swing ...

Please be aware that the seller will not cover the cost of the return label. It is the customer's responsibility to generate the return shipping label and send the system back to our warehouse.

What isRPDAin cardiology

Prop 65 Warning: WARNING This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. More Information

Rpdacabg

Items must be returned within 30 days after receiving your order. Items must be returned in the same condition in which they were received, be unworn/unused, have any tags still attached, and include all the original packaging.

6 Febco 805Y Complete Rebuild Kit. Category: Febco 902-469. Call for price: $59.99 / EA / Part Number: 902-469.

Powers Process Controls. Condition: New. Reference: 20E206 CC. Sorry, This item is out of stock. $999.00. Add to cart.

RP Data login

Zurn's Thermostatic Mixing Valves provide safe storage and distribution of hot water for any application while ensuring safety.

Standard shipping normally takes 3-9 days. Next-day shipping is available on all domestic orders (for an additional charge). International shipping times depend on the products and destination (estimated at checkout).

10 In Cast Iron Reduced Pressure Detector Assembly Backflow Preventer, Domestic OSY Shutoff, Cubic Feet Meter, Epoxy Coated Using ArmorTek Technology

Discover top-quality RO systems, Aquarium RODI systems, whole-house water purification systems, and commercial water filtration systems.

We currently ship to the United States and Canada. To enquire about shipping to a different destination, please contact us.

Martinov offers a variety of radiant driveway snow melt systems that will enable you to stay warm and cozy in your home this winter.

50 GPD Reverse Osmosis Membrane Elements for Home Drinking Water Industry's most reliable method of water filtration Advanced membrane technology and automated fabrication for consistent performance Shipped dry for convenient handling and extended shelf-life Membranes rated at 50 psi, purifying 20% more water than competitors at 60 psi Model capacity: 50 GPD at 60 PSI We recommend changing your membrane every 2 years. Specifications 50 Gallon Per Day Membrane for Reverse Osmosis systems, fits all membrane sizes 1812-50 Removes particles down to 1/10,000th of a micron (98% removal of impurities) Membrane Features Stable, high rejection of contaminants even with high TDS water sources Advanced membrane technology with innovative thin layer composite design More consistent performance with less fouling, requiring less frequent cleaning 100% dry-stored membrane maximizing shelf life General Information Discard the first full tank of permeate; do not use for drinking or food preparation Keep membrane moist after initial wetting For prolonged system shutdowns, immerse membrane elements in a preservative solution Membrane shows some resistance to short-term chlorine contact Strictly follow operating limits and guidelines to maintain warranty validity