Febco® 825Y/825YA/825YAR Complete Repair Kit (Sizes 1 1/2, FRK112825YT, Febco® 825Y/825YA/825YAR Complete Repair Kit (Sizes 1 1/2"-2") · Febco ...

Series 009-AUS reduced pressure zone backflow preventer devices are designed to protect potable water supplies in accordance with national plumbing codes.

Hydronic radiant heating systems use hot water and a heat exchanger to transfer warmth inside homes and commercial spaces.

First and foremost, thermodynamic traps aren’t the most energy-efficient solution, since they can leak steam when they operate. Thermodynamic traps also generate a lot of intermittent noise, which can be bothersome in a work environment.

Even though they’re based on a fairly old design, inverted bucket traps are widely used because they’re reliable. They do have two disadvantages, though. First, the bucket can be easily crushed by a water hammer, so start up carefully. The second disadvantage, also found during startup, is that inverted bucket traps require priming to purge any collected air out of them so that it won’t displace steam.

Enter the condensate trap. Like its name suggests, the condensate trap separates liquid condensate from steam, so the steam can be reclaimed and continue on its journey while the liquid condensate drains away. There are four main kinds of condensate traps out there, each with their own set of advantages and disadvantages.

Installing a ReadyTemp® guarantees the most efficient control of your home’s hot water performance.  No other product on the market provides better comfort, more control, or improved efficiency.  With energy-saving features including "temperature based" cyclic pumping, adjustable temperature control, and scheduled-off "single-cycle" override, it's easy to see why ReadyTemp® is the industry’s "homeowner preferred" hot water circulation pump.

Other hot water circulators repeatedly place costly demand on home water heaters during everyday "cold water events" i.e. toilet flushing, etc

Backflow prevention valve. Prevents reverse flow due to both backsiphonage and or backpressure. For medium hazard applications.

Model M200, M200N · Stainless Steel Double Check Valve Assemblies with Tri-Link Check Valves for High Flow Fire Systems Size: 2 1/2 to 10 in. (65 to 250mm).

Buy Tekmar 680 Today. Free Shipping. Check the tekmar Snow Melting Control Outdoor Temperature Reset Speed Mixing ratings before checking out.

Inadequate flow of low-power circulators or thermostatic valve systems with uninsulated pipes/pipes in foundation/cold seasons

The whole point of a steam boiler system is to move heat from one place to another using water as a sort of “conveyor belt.” The water picks up the heat at one end of the system, takes it to the other end of the system, and offloads it.

ReadyTemp®'s Intelli-Circ Controller, Precise Adjustable-Temperature and Silent-Solenoid solves major inefficiencies and inconveniences common in today's hot water circulators and retrofit hot water circulating pumps

Thermodynamic condensate traps operate on a very simple principle: as condensate flows through the trap, it drops in pressure and releases flash steam. The pressure differential between this flash steam and the hot condensate in the trap causes a disc valve to open and close, allowing the condensate to drain away and the steam to flow through.

Thermostatic traps use temperature to separate steam and condensate. When steam enters a thermostatic trap, the heat causes a capsule in the trap to expand, closing off the drain valve. As more cooled condensate fills the trap, its lower temperature causes the capsule to shrink again. This opens the drain valve back up, allowing the condensate to drain away. Thermostatic traps are not only efficient, leaking effectively zero steam, they’re also repairable inline, so servicing doesn’t require a lot of disassembly work.

Image

Due to their design, float traps are very reliable. Modern designs also incorporate a thermostat that lets air evacuate from the system during startup if the boiler has been shut off and allowed to cool.

Have tank water heater and desire scheduled/timer+On-demand (push-button/wireless) lifestyle.  Order our TL4000 system.

Have tankless water heater and prefer scheduled / timer and/or On-demand (push-button / wireless) circulation operations.

Welcome to the Centre that centralises its focus on your child. Your child is in the core of our Learning Centre's four year integrated setup.

As we all know, when water is loaded up with heat, it undergoes a phase change from its liquid state to its gas state, which creates the steam we all know and love. At the end of the line, when the heat is offloaded, that steam condenses back into liquid water. That water has to be removed.

ReadyTemp® delivers the very best in hot water comfort, convenience and savings by eliminating numerous costly, comfort robbing  inefficiencies found in today's circulators, recirculators and on-demand systems. The inability to control both hot and cold water comfort, the inefficiency of continuous running pumps, the inaccuracies from pipe clamp-on temperature sensors and the costly waste of energy from repeated siphoning water from the hot water line to name a few.   Our philosophy, the sooner hot water is received at your desired temperature, the sooner very cold city water stops filling your water heater--water that would go down the drain, wasted.  ReadyTemp®'s temperature dial provides homeowners the means to control and optimize their home’s hot water convenience and comfort for maximum efficiency and savings.

TL5000N  $639.00   No Dedicated return line / Cold line as return (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011

TL5000D  $585.00   Dedicated return line (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011 Stainless Steel Pump

If the steam and condensate were allowed to flow back through the system together, it reduces efficiency because steam transfers heat far better than water. Plus, keeping steam and condensate together would mean reheating steam that was already hot enough. Which wastes even more energy.

ATC3000 OPTIMIZER ATC3000 TANK WATER HEATER UNDER SINK INSTALL EASY 3-STEP INSTALL CONNECT 4 HOSES 2 HW HOSE / 2 CW HOSES 6"H X 7"W X 7"D 0.52 AMPS 1/40TH HP MAX 125' TO W.HEATER IDEAL SCHEDULED/TIMER        FULL SPEC'S IN BROCHURE           CLICK TO READ MORE

WARE is an industrial & commercial boiler rental and service company that specializes in sales, service, valve repair, rentals, parts, turn key and boiler training.

TL4000N  $489.00   No Dedicated return line / Cold line as return (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008

ReadyTemp® monitors temperature using a "precision grade" stainless steel "water contacting" temperature probe. It consistently and accurately measures temperature, cycling the internal TACO pump, only as needed, maintaining water at the homeowners dialed-in temperature.  ReadyTemp®'s unique space-industry engineered manifold achieves ‘positive bypass flow restriction’ using an integrated ‘normally closed’ solenoid valve for industry-record efficiency and savings.  This more efficient bypass valve prevents any water from siphoning out of the hot water line and into the cold water line during the homeowner’s use of cold water inside or outside of the home.  Inefficient ‘normally open’ thermostatic bypass/comfort valves remain open any time 95F or hotter water is not present in the line resulting in repeated, unnecessary and expensive demand on the water heater. This costly, inefficient siphoning occurs as a result of the imbalance in water pressures between the hot and cold water lines during cold water use. Higher pressure in the hot water line forces water into the cold line, even during the use of cold water only. This siphoned water is then replaced by cold city water entering the home’s water heater. With Inefficient hot water recirculators, every instance of cold water use, whether at the kitchen tap, the bathroom toilet, or the garden hose, results in extra demand on the water heater.

TL4000N   &     TL5000N COLD LINE AS RETURN TANK OR TANKLESS W.HTRS HEATER* OR SINK INSTALL SAME 4-HOSE 3-STEP => CONNECT 4 HOSES 2 HW LEFT / 2 CW RIGHT 6¾"H X 13½"W X 7"D * 0.79 AMPS 1/25TH HP * 16' HEAD 1 - 14 GPM IDEAL ALL-IN-ONE SYSTEM FULL SPEC'S IN BROCHURE  CLICK TO READ MORE

Anti-siphon solenoid, 2 isolation valves, Power cord, two (2) Flex lines, 20 event Timer, Install Guide, 2 yr warranty

Industry record efficiency; intelli-Circ on-board microcontroller, cyclic-pumping, anti-siphon solenoid prevents costly HW demand

Anti-siphon solenoid, 2 isolation valves, Power cord, two (2) Flex lines, 20 event Timer, Install Guide, 2 yr warranty

Image

Optimizer Control Box,  Built-in check valve, two (2) isolation valves 1/2" or 3/4" female connections, Temperature probe

WARE is experienced in the installation, service, and repair of all types of condensate traps. If you need one, or need one fixed, we’re here to help.

Pipe fittings for dissimilar materials allow incompatible materials to be joined together safely. Dielectric unions and flanges provide insulation between ...

Float condensate traps operate under the principle that condensate is denser than steam. Inside a float trap, you’ll find -- you guessed it – a float. As condensate builds up in the trap, it causes the float to rise. This opens a valve to drain the condensate away. Once the condensate is gone, there’s nothing left but steam. At this point, the float drops and the drain valve closes.

Washing machine valves use a knob or lever to manually start and stop the flow of cold or hot water.

Optimizer Control Box,  Built-in check valve, two (2) isolation valves 1/2" or 3/4" female connections, Temperature probe

CONTROL / ACTIVATION and WIRELESS OPTIONS 2016 BROCHURE / SPECIFICATIONS TL-Series Install / User Guide ATC3000 Install / User Guide As FEATURED in GIPRO Presentation Materials and Manuals      SYSTEMS SHIP COMPLETE NO ADDITIONAL PARTS NEEDED (UPS Ground / Tracking Info sent to your email)

ReadyTemp®'s temperature-based cyclic system pumps water that is lower than the homeowner’s selected temperature out of the hot water line, into the cold water line, and then back into the water heater.  This cyclic-pumping consumes less energy compared to top-mounted hot water recirculators which pump continuously during scheduled-on periods.  Cyclic pumping benefits comfort as well by providing a home’s cold water pipes the seconds needed to absorb the warmer water that has been passed from the hot water line.  As a result, the homeowner does not waste water, time and energy waiting for cold water, a frequent complaint by owners of other hot water circulation pumps.   ReadyTemp®'s normally closed solenoid valve provides unsurpassed comfort in that it's not vulnerable to pressure fluctuations during cold water use, unlike inferior thermostatic valve and spring-based check valve designs that cannot prevent siphoning from the hot water line during cold water usage.

TL4000D  $435.00   Dedicated return line (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008 Stainless Steel Pump,

Image

A TMV blends hot and cold water before reaching the outlet, ensuring safe kitchen, laundry, shower and bath temperatures and preventing scalding. CRG Plumbing & ...

CHOOSE:  TL4000(N or D) N=No dedicated return line (will use cold line as return)  D=Dedicated return line already exist in home

TL4000D    &       TL5000D  with DEDICATED RETURN TANK OR TANKLESS W.HTRS MOST ANYWHERE ON LOOP     * YLW =TL4'S  *BLK =TL5'S CONNECT SUPPLY / RETURN CONFIG'S TO "ANY" LIFESTYLE 6¾"H X 10"W X 7"D * 1.76 AMPS 1/8TH HP * 30' HEAD 1 - 28 GPM WITH ½" OR ¾" FLANGES        FULL SPEC'S IN BROCHURE        CLICK TO READ MORE

There are several advantages that thermodynamic traps offer. They’re small and fairly cheap, they’re robust, and they can operate under high pressures. Since they really only have one moving part, thermodynamic traps are also easy to service. However, there are disadvantages.

Inverted bucket traps work by opening and closing a valve connected to a cylinder that resembles an upside-down bucket. As steam collects in the bucket, it causes the bucket to float higher and higher on the condensate collecting below it. When the bucket rises high enough, it opens the valve and the condensate drains away.