In water distribution systems, water is normally maintained at a significant pressure to enable water to flow from the tap, shower, or other fixture. Water pressure may fail or be reduced when a water main bursts, pipes freeze, or there is unexpectedly high demand on the water system (for example, when several fire hydrants are opened). Reduced pressure in the pipe may allow contaminated water from the soil, from storage, or from other sources to be drawn up into the system.

It is no more challenging to repair a water pressure-reducing valve than fixing the kitchen faucet. Q: How does the City's AMI project affect my PRV? A: While ...

HOSE,GAS,3/4"X60",W/DISCONECT.

Flomatic

The best places are either close to the pump, isolation or check valve that is originating the hammer, or at more distant points where the pipe changes ...

To prevent contamination due to back pressure, many health regulatory regimes require an air gap or mechanical backflow prevention assembly between the delivery point of mains water and local storage or use.[2] Where submerged mains inflow is permitted,[further explanation needed] a backflow prevention assembly is required, which protects the potable water system from contamination hazards. A check valve is a basic form of backflow prevention, but often more complex devices are required because check valves are not considered to be reliable, when compared to more sophisticated devices with redundancies and reduced-pressure zones.[further explanation needed]

The simplest, most reliable way to provide backflow prevention is to provide an air gap. An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool. A simple air gap has no moving parts, other than flowing water. Many plumbing codes specify a minimum air gap distance required for various circumstances, such as a drain connection for a dishwasher, e.g., BS 6282.

Image

Can't find what you are looking for? Please fill out our non-stock/special order form and we'll get right back to you. Thanks!

Backflow means the undesirable reversal of flow of a liquid, gas, or suspended solid into the potable water supply; a backflow preventer is designed to keep this from happening. Points at which a potable water system connects with a non-potable water system are called cross connections. Such connections occur naturally in appliances such as clothes washers and dishwashers, but they must be carefully designed and installed to prevent backflow. Another common location for a backflow preventer is the connection of a fire sprinkler system to a water main, to prevent pressurized water from flowing from the fire suppression system into the public water supply.

Alternatively, a specialized backflow preventer valve may be installed at strategic locations in the plumbing system wherever there is a risk of contaminated fluids entering the water supply pipes. These valves are used where there is not sufficient vertical clearance or physical space to install an air gap, or when pressurized operation or other factors rule out use of an air gap. Because these valves use moving parts, they are often required to be inspected or tested periodically.

Dielectric unions are used to separate two dissimilar metal pipes (such as copper pipes and galvanized steel). Purpose of dielectric unions is to prevent ...

Back-pressure occurs for example when air is blown through the straw and bubbles begin to erupt at the submerged end. If, instead of air, natural gas had been forced into a potable water tank, the gas in turn could be carried to a kitchen faucet. This is an example of a direct cross-connection, with undesirable material being pushed into the system.

Browse Thermostatic Air Vent For Steam Systems in the Colton Industries catalog including Item Number,Size,A,B,Max. Oper. Press. PMO,Max. Oper. Temp. TMO.

Back pressure can force an undesirable contaminant to enter potable water piping. Sources of back pressure may be boilers, heat exchanging equipment, power washing equipment, fire sprinklers, or pumps in the water distribution system. In some cases there may be an almost continuous risk of overcoming the static water pressure in the piping. To reduce the risk of contamination, a backflow preventer can be fitted. A backflow preventer is also important when potentially toxic chemicals are used, for instance for commercial/industrial descaling of boilers, or when chemical bleaches are used for residential power washing.

In many countries. approved backflow prevention assemblies are required by law, and must be installed in accordance with plumbing or building codes.[example needed] A typical backflow assembly has test cocks and shut-off valves, and must be tested when installed, if relocated or repaired, and also on a periodic basis.[citation needed]

FEBCO Reduced Pressure Model 825Y Size 3/4

FEBCO

Backflow Direct carries code compliant, high quality air gaps for Ames Deringer, Magnum, Colt and SS Series backflow preventers. View as Grid List. 4 Items.

A closely related device is the backwater valve, which is designed to prevent sewage from backing up into a building and causing basement flooding.[1]

Image

Febco765

TEKMAR 150 ONE STAGE SETPOINT CONTROL. Item. 8997. UPC. 77965501500. Pending Reviews. Customers Also Bought... AXIOM DMF-150 DIGITAL MINI GLYCOL FEEDER 4.5 ...

In the US, the Environmental Protection Agency (EPA) holds local water suppliers responsible for maintaining a certain amount of purity in potable water systems. Many states and/or local municipalities require annual testing of backflow prevention assemblies. In most cases, the law requires a double check (DC), reduced pressure principle device (RP) device, or an air gap when backflow prevention is mandated.[citation needed]

Shop a wide selection of Backflow Preventer Parts at our online store. Find top-quality parts for your backflow prevention system today!

WattsBackflow preventer

Back-siphonage occurs when higher pressure fluids, gases, or suspended solids move to an area of lower pressure fluids. For example, when a drinking straw is used to consume a beverage, suction reduces the pressure of fluid inside the straw, causing liquid to move from the cup to inside the straw and then into the drinker's mouth. A significant drop of pressure in a water delivery system creates a similar suction, pulling possibly undesirable material into the system. This is an example of an indirect cross-connection.

Series 522. Adjustable thermostatic mixing valve. For installation under hot water storage heaters. Go to. Product Description, Technical data ...

Image