A water heater pressure relief valve, also referred to as a T&P valve, pressure relief valve, or water heater temperature valve is a safety feature that you can find on any water heater. The reason it’s there is to keep you safe in case the water pressure is too high.

If your valve is sticky, then it becomes stuck in a closed (downward) or open (extended position). If it’s closed, then the valve won’t be able to relieve the heat or pressure that builds up in the closed water heater system. There could be a rupture as a result.

The RPZ is only approved for horizontal installation. This is because the vent to drain the water away must be the lowest point of the installation and this cannot be guaranteed in a vertical installation.

The first is easy. It is good practice to support the device so that its weight doesn’t cause any strain on the pipe work. Use a commonsense approach and ensure the finished job is commensurate with the professional you are.

This is for safety reasons. Everything has been done according to standards that have been mandated by plumbing codes. So if you’re having any issues with the valve, you’ll have to call a professional to have it fixed.

To get started, identify where the relief valve shut off is. Usually, you can find it upon the cold water feed, which is on top of the water tank, on the right side where the inlet is.

If you suspect there’s a problem with your water heater pressure relief valve, you can do a test. This is actually a good idea if you don’t have any problems at all, as this type of maintenance will protect your water heater—and yourself.

Backflow prevention devices are very simple mechanical valves that stop the reversal of flow of drinking water. Each device is marked with the direction of flow as they can only operate in one direction.

This said, considering that there might be other issues causing discharge tube problems—issues connected to high water pressure or temperature—it’s safest to have a professional deal with this too.

Why is my Hot Water Cloudy? Have you ever been in this situation? You turn on the hot water, and water splashes around and the […]

If a water pressure issue is what is causing the water heater pressure relief valve to not work, then it might be dangerous for you to change the valve yourself. Generally speaking, it’s a good idea to hire a professional to protect yourself.

The second is much more difficult. All device manufacturers provide information on the discharge volumes that RPZs will dump at various pressures. Devices will dump water for a number of reasons. One is pressure fluctuations. This will cause the device to spit water from the relief vent and often will not cause more than a minor inconvenience. Another is the device will empty all the water from within the valve should a negative supply incident occur. This can be a large volume depending on the size of the device; 15mm may be a cup full, 250mm will be a bucket or more. The other reason is a massive failure whereby through either the head pressure within the piping system or a ring main feed, the device goes fully open and discharges continually at full back pressure.

If you’ve been noticing any issues with your water heater pressure relief valve, then you need to know where it is on your water heater. Usually, you can find it on the top or side of this appliance. The valve connects to a plastic or metal discharge tube that runs down the side of the tank.

A water heater pressure relief valve, also referred to as a T&P valve, or water heater temperature valve is a safety feature that you can find on all water heaters. The reason it’s there is to keep you safe in case the water pressure gets too high.

Without this safety feature, your water heater could end up breaking. You could potentially end up with burns if the high water pressure is dangerously high.

This valve also ensures that there aren’t any leaks in your water heater, which would lead to low water pressure when you want to use it to wash the dishes or take a shower.

This is where the drain size is critical and could mean the difference between an inconvenience and a large cleanup cost and potential insurance claim/litigation case. Your customer expects the designer and the installer to understand the operation and potential issues so ensure you know what the device manufacturer recommends for their device.

If your valve is working, this is when it will open. This releases steam and hot water from the discharge tube, making your water heater operate safely again.

Here’s how it works. Whether your water heater is heated by electric heating elements or a gas burner, both the metal tank and the water inside expand when the hot water temperature is somewhere between 120 and 140 degrees.

Once you’ve done this, take a look at the discharge tube to make sure that it’s attached firmly. Then, take a bucket and put it under the discharge tube.

Ensure you read the installation instructions supplied with the valves or ask your supplier for some training. Ongoing skills based training and development can assist with minimising the chance of unexpected pain and suffering.

Protection of the drinking water comes at the expense of the available pressure, but a mechanical device is still often a better option than a complete break and re-pressurisation.

Your water heater is leaking? Make sure that it doesn’t come from the valve before replacing it. If your pressure relief valve is leaking, then this may be because it isn’t seated properly in the tank’s threaded opening. This is quite a common issue if you’ve recently replaced your old valve with a new one.

With the use and installation of backflow prevention devices being commonplace now since the mid-90s, you’d think the industry would have a good handle on the installation requirements and the hydraulic aspects of how they work.

However, when the temperature is 210 degrees—or the pressure is 150 psi (pounds per square inch)—t his is far too much pressure and heat in the water heater tank. If it’s the case, you should change your hot water heater temperature or verify your heater thermostat.

To avoid draining the hot water heater or replacing the valve every so often, install the Corro-Protec powered anode to solve those two issues.

When your water heater pressure relief valve isn’t functioning properly, it’s usually for one of two reasons. It either sticks so that it doesn’t properly open or close, or it has a leak, which means that it’s continually dripping, lowering your water pressure.

Now, pull the metal lever of the valve slightly, so that a small amount of the water—a quarter cup or so—discharges into the bucket.

The backflow prevention device uses force-closed, spring-loaded check modules that close when the incoming water pressure drops below the spring tension setting. The very fact that the incoming water has to overpower a spring means there will be a pressure loss across the check valve. The degree of this pressure loss will depend on the type of device installed.

The water heater pressure valve is in place so that it can relieve excess pressure and temperature in a water heater if either of these is too high. Because this everyday appliance is a closed system, thermal expansion occurs in water heaters.

The DCV can be installed in both vertical and horizontal applications as long as there is adequate spacing around the device for maintenance, testing and repair.

The Reduced Pressure Zone device (RPZ) also has two independently operating check valves within the same body but has a differential pressure relief valve that opens to atmosphere so that water will be drained from the device if a backflow incident occurs. To ensure the relief valve operates as it should, the spring tensions in the checks must be different enough to provide a safety margin, otherwise the device would continually drop water from the vent due to supply main pressure fluctuations. This extra safety comes at the expense of a higher pressure drop across the device as the spring tension on the first check must exceed 35Kpa and the tension on the second check must exceed 7Kpa. Again, experience shows that this 42Kpa is not achievable and the pressure drop across an RPZ is more likely to be above 65Kpa.

It’s important to maintain the correct pressure in a hot water heater for efficient performance and safety. But what happens when the pressure gets too […]

Fortunately, by understanding how relief valves work, you can solve whatever problem you’re having with the one on your water heater. In this article, we’ll review everything you should know about this valve.

If you’ve been having issues with your water heater recently, this article is for you! You might find that you’re paying high energy bills, not getting access to hot water when you want it, or your water pressure is low. This can be frustrating, but what’s the cause? You might be having a problem with the water heater pressure relief valve.

Finally, release the level so that it quickly snaps into the original position. If it doesn’t snap quickly into this original position, then your water heater valve isn’t working and needs to be replaced.

Image

Peter McLennan dispels some myths surrounding the two main backflow prevention devices seen today: the reduced pressure zone device (RPZ) and the double check valve (DCV).

Finally, you can get hot water at the right pressure again, enjoying your morning shower like you used to. Read on to learn more.

This said, if you’re only having issues with the discharge tube, this is easy to replace. You won’t have to drain your water heater, and you can deal with it yourself.

Sometimes, you can easily fix this problem by opening and closing the valve lever a few times. However, if it continues to stick, then you’ll need to replace it.

The Double Check Valve (DCV) has two independently operating check valves within the same body. To comply with the Australian Standards the spring settings must exceed a differential across each check valve of 7Kpa. This means the minimum pressure drop across a DCV should be 14Kpa. In reality, 14Kpa is not achievable due to the tolerances in springs and the flow passages through a backflow preventer. Experience indicates that a DCV has a pressure drop in the vicinity of 25Kpa, but this also depends on the manufacturer and the age of the device as springs tend to go soft over time.

The water heater pressure is already installed when you receive your water heater (or buy a home that has one already). It’s actually welded onto the tank; you’ll see a threaded inlet where it is.