On homes built after 2010, it is more common to find them in other places. Check in the garage for a wall panel with plumbing pipes inside. We have also located them in the walls under stairs, closets, and laundry rooms.

If your faucets, toilets, or appliances need frequent repair, this could be a symptom of high water pressure. Most fixtures are rated for a maximum working pressure of 80 psi. If you have a pressure that is continually higher than this, parts will wear out and things will break more quickly.

In this article, your local plumbing experts explain the symptoms of a bad pressure reducing valve that may need to be replaced.

Repetitive knocking or consistent humming noises that seem to come from the walls when you run different fixtures are often caused by a failed PRV.

It is sometimes possible to adjust the pressure at the PRV to lower it. However, if the PRV is more than a few years old, this is often risky. By attempting to adjust it, it may stop working altogether or even start leaking.

Thermal expansion tanks are designed for pressure control in potable water systems. The building’s water heater or water heating system typically creates thermally expanded water. A properly sized thermal expansion tank will accommodate this additional volume of water through expansion during the heating cycle and control the system pressure increases, keeping pressures from reaching critical limits. The tank uses compressed air to maintain system pressures by accepting and expelling the changing volume of water as it heats and cools. These tanks are designed using a flexing Butyl barrier that separates the stored water from the captured pressure control air cushion. This barrier, a replaceable bladder or fixed diaphragm, allows the water to be contained within the bladder preventing corrosion and potential water logging. The thermal expansion tanks are engineered to meet ASME standards, and are also available in non-code designs. Wessels thermal expansion tanks are offered in industry’s broadest range from 2 to 4,000 gallons and up to 250 PSI.

Potable water expansionvessel sizing

The diaphragm tank has been developed to allow the systems air cushion to be separated from the systems water. No waterlogging of the tank can occur as the air is held between the tank wall and the outside of a bladder placed inside the tank, while the system water is contained inside the bladder. This changes the system to an air elimination system, as any air extracted from the system water is passed out of the system into the atmosphere.

Legacy Plumbing’s service area is on the north side of the Dallas Metroplex. Most of the PRVs around here are located on the main water line right where it comes up under the perimeter of the home in the front flower bed.

Waterheaterexpansiontank

These noises can also be caused by other things as well, such as a failed expansion tank, quick closing solenoid valves on new appliances, bad vacuum breakers, faulty valves with loose washers, worn-out toilets fill valves, improperly strapped pipes, etc.

Wessels is America's leading supplier of custom & specialty tanks in Indianapolis, Carmel, Bloomington, Columbus, Evansville, Terre Haute, Lafayette, Ft. Wayne, South Bend, Indiana as well as Chicago, Quad Cities, Illinois, Des Moines, Iowa, Columbus, Cincinnati, Ohio, Detroit, Michigan, Louisville, Lexington, Kentucky, Minneapolis, St. Paul, Minnesota, Madison, Wisconsin, St. Louis, Missouri and other areas throughout the Midwest and the United States.

Bladder tanks are required in a closed-loop heating or chilled water HVAC system to absorb the expanding fluid and limit the pressure within a heating or cooling system. A properly sized expansion or compression tank will accommodate the expansion of the system fluid during the heating or cooling cycle without allowing the system to exceed the critical pressure limits of the system.

wattspotable water expansiontank plt-5

Few things are as essential as plumbing fixtures when maintaining and enhancing your home’s comfort. These fixtures help keep the water flowing where it’s needed

The PRV won’t last forever, though. They are made with rubber parts and springs that will eventually wear out or get gummed up with particles in the water. Usually, PRVs fail slowly over time. It may take a while for you to notice there is an issue, especially if your usage habits aren’t very demanding.

Expansion tanksfor boilers

Image

Frisco, Texas, is one of the best places to live in the US, thanks to its thriving economy, glorious landscapes, and reputation as one of

If your water pressure doesn’t seem to be as strong as it once was or you notice a significant loss of pressure when you use more than one fixture at the same time, your pressure reducing valve may be bad. If you don’t usually use different tubs and showers at the same time, you may first notice this issue when you have guests over and the demand is higher than normal.

Pressurized thermal expansion tanks differ from plain steel expansion tanks in that a flexible bladder or diaphragm separates the air cushion from the system fluid. The air side pre-charge of the tank must be field adjusted to equal the system supply pressure. As the system water expands, the bladder expands open, pushing against the air cushion to accept the expanded water.

Expansiontank chilledwatersystem

Sometimes it can be a combination of these contributing factors. For more confirmation that the sound is caused by the PRV, go to where it is located and listen. It should be noticeably louder right next to the PRV.

Image

Wattsexpansiontank sizing chart

Potable waterthermalexpansiontank

Check out all of our Ace Hardware Home Services locations at:Home Maintenance Services & Repair | Ace Hardware Home Services

The Pressure Reducing Valve (PRV) protects your home from water pressure that is higher than what the plumbing fixtures in your home were designed to handle. By code, water pressure inside your house should be between 40-80 pounds per square inch (psi). If the water pressure delivered by your water supplier is higher than that, a pressure reducing valve is installed on the main water line serving the home to bring this down to an appropriate level.

When PRVs start to wear out, they can cause many strange issues with the water pressure throughout your home. As we go through these different symptoms, it is important to know that they will usually occur all over the house at the same time when they are caused by a failed PRV. If you are having any of these issues on only a single fixture in your home, then the issue probably isn’t with the PRV.

Image

You might expect ghosts and ghouls from horror stories, right?  But a different kind of nightmare scares many adults — and it’s not haunted houses.

Although PRV issues usually happen slowly, sometimes problems can crop up overnight. If you have no water pressure throughout the house on both the hot and cold, your PRV may be bad. Make sure you check both the hot and cold water. If there is good pressure on the cold and not the hot it may be an issue with the water heater or the fixture itself.

Bestpotable water expansion tanks

Sometimes the valve itself will burst and start leaking. If you have a muddy or flooded spot in the flower bed, this could be the reason.

Hopefully, this information helps you out. If you have any questions, feel free to give Legacy Plumbing a call. We are happy to help in any way we can.