Contact Fallon Solutions to book your yearly thermostatic mixing valve testing on 1300 054 488 or complete our plumbing enquiry form and one of our friendly team will contact you.

Have tankless water heater and prefer scheduled / timer and/or On-demand (push-button / wireless) circulation operations.

Thermostatic mixing valves must be installed and serviced annually to comply with the National Plumbing and Drainage Code AS 3500. According to legislation, these valves require servicing and maintenance at intervals no greater than 12 months. Our administration team can schedule annual maintenance, ensuring compliance with relevant legislations.

ATC3000 OPTIMIZER ATC3000 TANK WATER HEATER UNDER SINK INSTALL EASY 3-STEP INSTALL CONNECT 4 HOSES 2 HW HOSE / 2 CW HOSES 6"H X 7"W X 7"D 0.52 AMPS 1/40TH HP MAX 125' TO W.HEATER IDEAL SCHEDULED/TIMER        FULL SPEC'S IN BROCHURE           CLICK TO READ MORE

Image

Waterheatercirculation pump

Image

Water circulation PumpGrundfos

ReadyTemp® delivers the very best in hot water comfort, convenience and savings by eliminating numerous costly, comfort robbing  inefficiencies found in today's circulators, recirculators and on-demand systems. The inability to control both hot and cold water comfort, the inefficiency of continuous running pumps, the inaccuracies from pipe clamp-on temperature sensors and the costly waste of energy from repeated siphoning water from the hot water line to name a few.   Our philosophy, the sooner hot water is received at your desired temperature, the sooner very cold city water stops filling your water heater--water that would go down the drain, wasted.  ReadyTemp®'s temperature dial provides homeowners the means to control and optimize their home’s hot water convenience and comfort for maximum efficiency and savings.

Anti-siphon solenoid, 2 isolation valves, Power cord, two (2) Flex lines, 20 event Timer, Install Guide, 2 yr warranty

ReadyTemp®'s temperature-based cyclic system pumps water that is lower than the homeowner’s selected temperature out of the hot water line, into the cold water line, and then back into the water heater.  This cyclic-pumping consumes less energy compared to top-mounted hot water recirculators which pump continuously during scheduled-on periods.  Cyclic pumping benefits comfort as well by providing a home’s cold water pipes the seconds needed to absorb the warmer water that has been passed from the hot water line.  As a result, the homeowner does not waste water, time and energy waiting for cold water, a frequent complaint by owners of other hot water circulation pumps.   ReadyTemp®'s normally closed solenoid valve provides unsurpassed comfort in that it's not vulnerable to pressure fluctuations during cold water use, unlike inferior thermostatic valve and spring-based check valve designs that cannot prevent siphoning from the hot water line during cold water usage.

Industry record efficiency; intelli-Circ on-board microcontroller, cyclic-pumping, anti-siphon solenoid prevents costly HW demand

Water Circulation Pumpfor Fish Tank

Optimizer Control Box,  Built-in check valve, two (2) isolation valves 1/2" or 3/4" female connections, Temperature probe

TL5000N  $639.00   No Dedicated return line / Cold line as return (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011

Other hot water circulators repeatedly place costly demand on home water heaters during everyday "cold water events" i.e. toilet flushing, etc

12V HotWater Circulation Pump

ReadyTemp®'s Intelli-Circ Controller, Precise Adjustable-Temperature and Silent-Solenoid solves major inefficiencies and inconveniences common in today's hot water circulators and retrofit hot water circulating pumps

Optimizer Control Box,  Built-in check valve, two (2) isolation valves 1/2" or 3/4" female connections, Temperature probe

CHOOSE:  TL4000(N or D) N=No dedicated return line (will use cold line as return)  D=Dedicated return line already exist in home

A thermostatic mixing valve calculates hot and cold water input flows to ensure the correct output temperature. While hot water storage is required at 60 degrees Celsius to inhibit Legionella bacteria growth, the safe tap water temperature should not exceed 50 degrees Celsius to prevent scalding. Fallon Solutions conducts thermostatic valve testing to verify that your hot water meets the correct temperature standards.

Fallon Solutions recommends installing a thermostatic valve on all hot water systems in homes and businesses to prevent burns and scalding. Did you know you can receive third-degree burns in as little as 1 second when exposed to hot water between 65 and 80 degrees Celsius. Fallon Solutions, with its team of master plumbers, is your trusted supplier, tester, and installer of thermostatic mixing valves. These valves guarantee the safe delivery of hot water in your home or workplace.

ReadyTemp® monitors temperature using a "precision grade" stainless steel "water contacting" temperature probe. It consistently and accurately measures temperature, cycling the internal TACO pump, only as needed, maintaining water at the homeowners dialed-in temperature.  ReadyTemp®'s unique space-industry engineered manifold achieves ‘positive bypass flow restriction’ using an integrated ‘normally closed’ solenoid valve for industry-record efficiency and savings.  This more efficient bypass valve prevents any water from siphoning out of the hot water line and into the cold water line during the homeowner’s use of cold water inside or outside of the home.  Inefficient ‘normally open’ thermostatic bypass/comfort valves remain open any time 95F or hotter water is not present in the line resulting in repeated, unnecessary and expensive demand on the water heater. This costly, inefficient siphoning occurs as a result of the imbalance in water pressures between the hot and cold water lines during cold water use. Higher pressure in the hot water line forces water into the cold line, even during the use of cold water only. This siphoned water is then replaced by cold city water entering the home’s water heater. With Inefficient hot water recirculators, every instance of cold water use, whether at the kitchen tap, the bathroom toilet, or the garden hose, results in extra demand on the water heater.

TL4000N   &     TL5000N COLD LINE AS RETURN TANK OR TANKLESS W.HTRS HEATER* OR SINK INSTALL SAME 4-HOSE 3-STEP => CONNECT 4 HOSES 2 HW LEFT / 2 CW RIGHT 6¾"H X 13½"W X 7"D * 0.79 AMPS 1/25TH HP * 16' HEAD 1 - 14 GPM IDEAL ALL-IN-ONE SYSTEM FULL SPEC'S IN BROCHURE  CLICK TO READ MORE

CONTROL / ACTIVATION and WIRELESS OPTIONS 2016 BROCHURE / SPECIFICATIONS TL-Series Install / User Guide ATC3000 Install / User Guide As FEATURED in GIPRO Presentation Materials and Manuals      SYSTEMS SHIP COMPLETE NO ADDITIONAL PARTS NEEDED (UPS Ground / Tracking Info sent to your email)

Fallon Solutions recommends installing a thermostatic valve on all hot water systems in homes and businesses to prevent burns and scalding. These valves need to regulate outlets at temperatures no greater than 50 degrees Celsius in domestic settings and 45 degrees Celsius in places such as:

Image

Coldwater circulation Pump

Solarwater circulation pump

TL5000D  $585.00   Dedicated return line (Adj Flow 2 to 30 GPM, 31 ft head, 1/8hp) TACO 011 Stainless Steel Pump

Inadequate flow of low-power circulators or thermostatic valve systems with uninsulated pipes/pipes in foundation/cold seasons

Have tank water heater and desire scheduled/timer+On-demand (push-button/wireless) lifestyle.  Order our TL4000 system.

By submitting, you authorize Fallon Solutions to send text messages with offers & other information, possibly using automated technology, to the number you provided. Message/data rates apply. Consent is not a condition of purchase.

Call now on 1300 054 488 – We Can Be There Today! We are also available 24/7 for hot water emergencies in the Greater Brisbane area. If you prefer to send an enquiry contact us here. Or book online below.

TL4000N  $489.00   No Dedicated return line / Cold line as return (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008

Anti-siphon solenoid, 2 isolation valves, Power cord, two (2) Flex lines, 20 event Timer, Install Guide, 2 yr warranty

TL4000D  $435.00   Dedicated return line (Adj Flow 1 to 14 GPM,16 ft head, 1/25hp) TACO 008 Stainless Steel Pump,

TL4000D    &       TL5000D  with DEDICATED RETURN TANK OR TANKLESS W.HTRS MOST ANYWHERE ON LOOP     * YLW =TL4'S  *BLK =TL5'S CONNECT SUPPLY / RETURN CONFIG'S TO "ANY" LIFESTYLE 6¾"H X 10"W X 7"D * 1.76 AMPS 1/8TH HP * 30' HEAD 1 - 28 GPM WITH ½" OR ¾" FLANGES        FULL SPEC'S IN BROCHURE        CLICK TO READ MORE

Installing a ReadyTemp® guarantees the most efficient control of your home’s hot water performance.  No other product on the market provides better comfort, more control, or improved efficiency.  With energy-saving features including "temperature based" cyclic pumping, adjustable temperature control, and scheduled-off "single-cycle" override, it's easy to see why ReadyTemp® is the industry’s "homeowner preferred" hot water circulation pump.