The corroded, leaking dielectric union in the back was installed by a ‘licenced plumber’. I installed the copper tube/hose and fittings. I paid quite a bit more for the brass fittings, I guess that is why people like the galvanized steel ones (cheap).
When there is a concern with using dielectrics, a plastic lined nipple have the ends of the plastic fold over the end of the nipple which provided an excellent dielectric. The plastic engages the thread of the fitting a attached, whether it be the tank of the piping, thereby insulating the metal nipple from the water. This prevents corrosion on either part. These nipples have been certified as dielectrics in numerous areas of the United States.
Texas plumbingContinuing Education2024
A dielectric union is designed to break the electrical contact between two dissimilar metals (to prevent galvanic corrosion). Most of the flexible copper connector hoses on water heaters have a plastic washer that acts as a dielectric union.
Plumbing Continuing Education courses can help you learn new skills and further develop skills you use regularly. JCCC’s Continuing Education Plumbing courses include:
Scholarships and other funding options are available for some Continuing Education courses. Funding Options for Continuing Education
CT Plumbingcontinuing educationonline
I’ve attached and old tech bulleting from Rheem on the topic. I’m not sure if it’s still accessible on their site. Also note that the nipples on top of the water heater are supposed to be dielectric, but as far as I know you can’t tell visually once the plumbing is hooked up.
The corrosive product often fills the pipe diameter restricting the water flow and is often the source of rusty water. Our company does not promote the use of dielectric unions, because they do not effect the corrosion characteristics of the water heater. Due to our cathodic protection system, the juncture of the supply piping and the tank fitting is adequately protected by the cathodic protection system against corrosion without the buildups which occur in the dielectric union.
Kansas and Missouri both require recertification every three years. JCCC also offers a Cross-Connection Control & Backflow Prevention Recertification Course to fulfill that requirement.
Any metal with a negative voltage when coupled with a metal with a more positive voltage potential will sacrifice (corrode) itself to protect the metal with more positive (noble) voltage. By placing a dielectric (insulating) fitting between two dissimilar metals, i.e. iron and copper, there is a break between the two. Therefore, in theory the iron will not corrode to protect the copper. In fact, the circuit is generally completed through the water, and depending on the water conductivity the iron will corrode at various rates.
The required use of dielectric unions on our water heaters is not necessary. With this in mind, uniformity of piping material must be administered by the installer. What is meant by this is “the piping used in the system i.e.: copper, etc. must be the same throughout, to and from the water heater”. When different piping material connectors are used, corrosion can be immediate and will commence deterioration within days of installation Why is this? When two or more different metallic piping materials are used there can be some level of electrical current flow between the materials due to their different levels of electrical voltage potential. By uniformly using the same material to pipe the water heater, there is essentially no difference in electrical potential between the piping and the water heater tank. Therefore, dielectric fittings are not required when following the uniformity of piping material.
The theory that is in practice is described as follows: All metals when immersed in an electrolyte, such as water, have a voltage potential. This voltage potential varies from approximately +3.0 volts to a –3.0 volts. The relative activity of the metal is determined by voltage potential with those metals with negative voltages being most active and more likely to corrode. Magnesium, for instance, has a slightly negative voltage, approximately –2.0 volts, and will corrode very rapidly in certain waters. Iron has a voltage potential of –0.4 volts and rusts (corrodes) very rapidly when exposed to a moist atmosphere. Copper on the other hand has a voltage potential of +0.350
The way I read it is that Dyelectric fittings are not to be used becase the SAME type of pipe is required throughout. Correct?
Dielectric unions may have been used many years ago and were installed with the thought to assist in reduction of corrosion that could develop at the piping connections. From time to time, this inquiry is brought to our attention stating the use of dielectric unions may be suggested required or should be, perhaps used.
Plumber continuing educationonline
You’ll learn the latest code requirements and information about cross-connection and backflow prevention through our ASSE-approved classes.
I hear ya. All you can do is your best. Kinda like how in Illinois we observe the plumbing which is worded differently from the other systems that we are required to inspect. Everyone says it is because of the plumbing union , but my opinion is it also has to do with not unscrewing and turning shutoff’s. Plumbing is like that as we all know.
Plumber continuing educationnear me
Ya I thought of that. Seems like the water heater would fail before serious dielectric corrosion. They only last 6 to 10 years here.
Plumber continuing educationfree
Visual inspection means just that. If you were unscrewing plumbing to check for missing parts , you, would have worse problems than lack of a proper dielectric union.
Plumbingcontinuing educationclasses near me
Where thereâs water, thereâs a need for plumbing. Plumbing as a trade is essential to maintaining our infrastructure and quality of life. Our Continuing Education Plumbing courses will prepare you for everything from solving your own plumbing challenges to handling the Master Plumbing Exam.
The installation of unions on the inlet and the outlet waterlines and a shut-off valve in at least the cold inlet waterline is recommended, so the water heater may be easily disconnected for servicing.
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373 Dielectric Technical Competence, Product Confidence Page 1 of 1 1221.doc Dielectric – an electricity, especially a substance with electrical conductivity less than a millionth (10 to the –6) of an MHO.
Probably better for the TX SOP to call out actual corrosion rather than all of the dielectric / non-dielectric scenarios or we’ll wind up with another SOP standard as silly and confusing to the public as the no AFCI defects in older homes.
Texas plumbingContinuing Educationcourses
The way I read it is that Dyelectric fittings are not to be used becase the SAME type of pipe is required throughout. Correct?
The way I read it is that Dyelectric fittings are not to be used becase the SAME type of pipe is required throughout. Correct?
A dielectric union is designed to break the electrical contact between two dissimilar metals (to prevent galvanic corrosion). Most of the flexible copper connector hoses on water heaters have a plastic washer that acts as a dielectric union.
These credentials help you stand out in the job market. You may even qualify for higher-paying roles and management positions.
IMO Dielectric unions have very limited benefit as the water within the pipe also conducts current, effectively defeating the “isolation” provided by the dielectric device. I see corroded nipples and fittings on and around water heaters all the time, regardless of whether dielectric isolated unions, couplings, connectors, etc. are used. Sometimes it’s caused by the copper flex connector with the integral isolator itself. Brass seems to have more universal compatibility, which is why I prefer to see brass nipples.
I did not look at the picture on your post earlier. the nipple on the cold water connection in the photo is shipped by the water heater mfg that are delivered to plumbing suppliers and are used to prevent a galvanic reaction. Because the fittings add about $5.00 to the cost of the heater retail stores such as Home depot buy their heaters with out the nipples. Most of the problems occur when water heaters are installed by homeowners that do not know any better or by the plumber that works out of the back of his truck
In the Cross-Connection Control & Backflow Prevention Certification, you'll learn about cross-connection, thermal expansion and other key concepts. You will take an exam to earn a certification to finish the course.
You can typically see part of the plastic washer/flange sticking out at the top of the fitting. This plastic fitting is frequently damaged when the fitting is tightened too much, causing a loss of the dielectric properties.
JCCC is dedicated to giving tradespeople opportunities to grow their skills. Following a Continuing Education path at JCCC has many perks, especially for those in plumbing. Here are a few things we offer students:
JCCC Continuing Education provides opportunities to enhance your knowledge and skills. Maybe you are a plumber who wants to expand your skill set, or maybe you want to learn a new trade. Every building requires plumbing — homes, a big corporate offices and medical facilities always need plumbers. And plumbers work on equipment like in-ground irrigation systems, food service equipment and commercial fire sprinklers. There is a nationwide shortage of skilled tradespeople, and plumbers are always in demand.