Backflow preventer febcoprice

Series 825YA Reduced Pressure Zone assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.This series prevents the reverse flow of contaminated water caused by backsiphonage or backpressure from entering the potable water supply. Ideal for protection at health hazard cross-connections in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. Applications also extend to irrigation systems, boiler feeds, water lines, and other installations requiring the highest level of mechanical protection. End connection specified NPT ANSI/ASME B1.20.1.To learn more visit: https://www.watts.com/floodprotectionsystem

The Zurn water hammer arrester is ideal for use where Lead-Free* fittings are required. Designed to protect residential, commercial and industrial water lines during pressure surges following quick valve closure. This excessive pressure surge is absorbed by the pre-charged cushion of air permanently sealed within the water hammer arrester. The water hammer arrester may be installed within a stud bay without the need for an access panel.

This series prevents the reverse flow of contaminated water caused by backsiphonage or backpressure from entering the potable water supply. Ideal for protection at health hazard cross-connections in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. Applications also extend to irrigation systems, boiler feeds, water lines, and other installations requiring the highest level of mechanical protection. End connection specified NPT ANSI/ASME B1.20.1.

Backflow preventer febcoinstallation

For product-specific approval information, please refer to the product’s specification sheet (see literature section above) or ask a Watts representative. For general information regarding any approval certification partners identified in the specification sheet, please visit our certification partners’ websites:

Series 825YA Reduced Pressure Zone assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

Backflow preventer febcomanual

20 Carr Road, Three Kings Auckland, New Zealand PO Box 27-555, Mt Roskill Auckland 1440 Ph: +64 9 624 1115sales@macdonaldindustries.co.nz

Maximum transient pressure surge, with arrester properly sized and placed in the water supply system, will not rise above 150 psi (1,050kPa) following quick valve closure. Maximum static pressure: 250 psi (1,720kPa). For best performance, static line pressure should not exceed 80 psi (550kPa); contact the factory for proper sizing if static pressure is greater. Max spike pressure 400 psi (2,750kPa). Nitrogen preload 60 PSI (415kPa).

W1260XL-A - 15mm Zurn water hammer arrester 159xØ22mmW1260XL-B - 20mm Zurn water hammer arrester 184xØ22mmW1260XL-C - 25mm Zurn water hammer arrester 159xØ28.6mmW1260XL-D - 25mm Zurn water hammer arrester 184xØ44mmW1260XL-E - 25mm Zurn water hammer arrester 159xØ64mmW1260XL-F - 25mm Zurn water hammer arrester 184xØ73mm