Sum total actual maintenance i've had to do is replace the fan in the combustion intake. $150' and 1 youtube video, plus 30 mins of my time.

Seriously, I don't get why I didn't know this/hadn't heard this before. I'm usually pretty good about basic maintenance around the house, but missed this boat so badly I wasn't even near when it arrived at its destination, much less seeing it leave the dock... EEK!

Not that it's relevant, but I have a 100 gallon tank that I use with my oil and pellet boilers. It has a 17 gallon corrugated (for Legionella) stainless steel coil inside for DHW. The tank shouldn't rust since it doesn't see oxygenated water. Of course, with that said, I just jinxed it.

Now, the one area, where Tankless sucks, is cost. New ones, with capacity similar to mine are Pricey, and a new install with a relocation...well, that Heat Pump WH is starting to look cheap.

Image

Water softener systemCostco

The water softener must regenerate once the resin bed becomes saturated with calcium & magnesium ions – recharging the bed once again with sodium ions.

From google: By replacing your anode rod every 3-5 years, your water heater can last well over 20 years without any risk of leaks and resulting water damage. Unfortunately, if you ignore this important water heater maintenance task, you may need to replace the entire water heater after only 10 years of use. Don’t tell the wife

Good water softener systemprice

Image

I looked long and hard at this the past couple of years because I am at the 10 year mark. So, it is just a matter of time on when I will be replacing my 50 gal.

BTW - kind of funny, the anode (looked at @aaiyar's link) looks like a used piece of junk...this is going to send me off into some additional reading about anodes as well.

For those searching for "water softener systems near me," Paragon Water in Houston and Dallas is the trusted water experts. We specialize in the best water softener systems for your home's or business' water, ensuring your water is consistently soft and free from hard minerals.

These one-of-a-kind combination systems offer the same high-quality product water of having separate softener and filter units in a space-saving, one-unit design. The Paragon Combo Series will remove hardness, bad taste and odor caused by chlorine, chloramines or organic matter.

Downflow water softener systems wash all the hardness & other debris through the clean portion of the bed – requiring it to be regenerated.

Good water softener systemaustralia

Which should help. My aunt had well water and when we sold her house it had a functioning gas water heater that was 25 years old.

Smooth process since the initial call all the way to the installation and last follow up call. Very good product with a reasonable price.

Good water softener systemfor home

When the (sacrificial) anode rod has disintegrated from corrosion, the corrosive minerals start attacking the tank itself. That’s why you have to replace the anode if you want your water heater to last.

Capacity. GPM varies with the incoming water temp, and the BTU capacity/efficiency of the WH. Mine will do 6.5 GPM on my well water, which i want to say comes into the house around 52F, and I have the output temp set to 130F. The heater can sustain this for as long as it has propane and water!

It is extremely simple to do. And with an impact wrench is a one-person job. Over the years, I've changed about 8-10 anode rods - both heaters combined, and using an electric impact wrench never damaged the tanks .....

Why the h*ll didn't you guys tell me this five years ago?! We need to have a meeting where you assume I'm an idiot (easy) and tell me all the obvious stuff I should already know.

Oh man...just not my morning. Going to shuffle off to my hole and reflect on my failings. I will take a bag of chocolate chip cookies with me to aid in my recovery.

My new house has the heater housed next to the car port. I am so glad I don't have to worry about a 100 gallons of hot water taking out the ceiling!

Reverse Flow Regeneration preserves an unused portion of softening bed from unnecessary exchange saving salt. ‘Supercharged’ bottom portion prevents slippage for softer, consistent quality.

Easy when your stuff is in the garage but mine is in the attic. Too much to screw with once a year or so. I looked long and hard at this the past couple of years because I am at the 10 year mark. So, it is just a matter of time on when I will be replacing my 50 gal. If is was in the garage I would just do it myself as I have done at other homes but the attic BS. Is a big NO for me. I have a leak sensor in the pan and hopefully I will replace it on my schedule and not at the mercy of the tank. And NO i don't like having 50 gallon of water sitting above the ceiling.

Water Softenerbunnings

In the house that I am selling in 6 days (closing next week!), I had two 50 gallon tanks in the attic. One supplied water to the upstairs, the other supplied water to the downstairs. 100 gallons in the attic regularly terrified me ... so I maintained them on a tight schedule for two things:

Puretecwater softener

Ricky provided outstanding service installing our whole house water softener system including RO in the kitchen. From clear communication to expert installation and great customer care, I highly recommend him.

That’s why they didn’t rust out. Nobody knows to change the anode, or how simple it is to do. I just changed the one in our camper which was down to about 1/8th inch thickness from 3/4 and it cost me $8. As far as preventative maintenance on our tankless water heater goes; I did it once on the one that was already installed when we moved into our current house and there was nothing but clear water after 10 years of neglect by the previous owners. 6 months later it died (I had already repaired it several times prior) and I installed a shiny new Rheem Platinum unit with remote temp control that I bought for $1500 at Home Depot (in stock) that can heat 9.5 gpm. I don’t plan on ever flushing it.

One of those heaters was installed in 2001. The second was installed in 2009. Both "6 year" heaters. While replacing the anode rods, I realized the 6-year heaters came with 0.75" diameter rod, while the 12-year heaters come with a 0.9" diameter rod. So I started using 0.9" rods. And placed leak sensors in the pans and had an automated main water valve.

Image

Recirculation: I find this feature to be unneeded. It truly doesnt take much longer to get hot water to the most distant tap in the house on my Rinnai, then it did on the tank. The key difference, is that some water in the hot water piping is pre-warmed by a tanked water heater, whereas in a tankless there is no such bleedover of heat, so a bit more cold water has to be expelled from the pipes to get hot water to the tap.

Good water softener systemreviews

Your tank should never leak. You may need the burner/thermostat to be adjusted or replaced, but the tank itself will stick around forever.

We aren't going to take it apart to see where the leak is coming from, but is the more likely statement that water is leaking from some fitting connected to the tank inside the water heater's outer skin? I really don't know anything at all about how water heaters are put together, I should do some reading...

I used to purchase them from Zoro. A 0.9" diameter magnesium anode that was 44" long used to be about $12-15. They are running about $30-35 now (post-pandemic).

Bestwater softenerAustralia

Maintenance: I didnt "flush" the system for the first 13 years, and I'm not convinced it is actually necessary, UNLESS you have unfiltered, hard well water.

I had a Great experience with these guys. The work was fast and efficient. Very professional environment but, what I liked the most was communication. I would recommend Simplisoft Water Systems to anyone, give them a chance.

Vent gas exhausting: mine uses a concentric intake/exhaust pipe and is mounted on an outside wall in my basement. The exhaust comes out at about 18" above ground at the rear of the house. Newer models seem to work differently though.

So is it wrong to assume the type of failure we had (leaking tank) isn't going to be put off by any particular maintenance? Or is there anything I should start doing w/the new water heater that would help postpone issues like leaks?

In downflow brining, we lose approx. 18% of our brine just from dilution in the freeboard and the size of the downflow injectors. Reference: Michaud C. (2002)