Air separatorfor chilled water system

The purpose of a vacuum breaker is to stop back siphonage. The atmospheric vacuum breaker consists of a check valve member and an air vent that is normally closed when the device is pressurized. The air vent allows air into the piping system for the purpose of stopping a siphon at the point of use (see Figure A). A common design element is that the air-inlet valve and check valve are nearly always the same mechanical component.

The continuous pressure restriction would no longer apply and would allow valves downstream and water pressure 24 hours per day. This type of assembly may be used only where outlet pressure will never exceed inlet pressure and is not subject to backpressure. This device may be installed indoors only if provisions for spillage from the dome are provided. They must be installed a minimum of 12 inches above the highest piping downstream of the PVB (see Figure C).

The spill-resistant type vacuum breaker is essentially a next-generation PVB. This assembly evolved because of the spillage encountered with the PVB. The function of the SVB is to eliminate the water spillage of the PVB.

A hose connection vacuum breaker should be installed on each faucet or hose bibb that is connected to the potable water supply to prevent backflow into the water supply. HVBs must be installed at least six inches above the ground surface. The HVB is an AVB and must follow the installation parameters of Table 603.2. Most HVBs have a set screw that prevents them from being easily removed once they are installed. This prevents them from being removed when the garden hose is removed. Once the HVB is installed, no further adjustments are required (see Figure B).

We understand that this is an inconvenience and are continually working with manufacturers to educate them on how MAP affects our customers.

Air separatorin HVAC

PVBs, therefore, are designed to operate under pressure for long periods of time without becoming inoperative. The internal check valves are spring-loaded so that any tendency for the valve to stick closed due to long periods of applied pressure and consequent fouling will be counteracted.The continuous pressure restriction would no longer apply and would allow valves downstream and water pressure 24 hours per day. This type of assembly may be used only where outlet pressure will never exceed inlet pressure and is not subject to backpressure. This device may be installed indoors only if provisions for spillage from the dome are provided. They must be installed a minimum of 12 inches above the highest piping downstream of the PVB (see Figure C).Spill-resistant vacuum breakersThe spill-resistant type vacuum breaker is essentially a next-generation PVB. This assembly evolved because of the spillage encountered with the PVB. The function of the SVB is to eliminate the water spillage of the PVB.

Air separatorpiping diagram

The spring-loaded check valve does not allow drainage of water from between the hose bibb and the upper part of the HVB; thus, freeze protection must be provided, just as all outdoor plumbing would need to be protected under freezing conditions.

Since our price for this product is lower then MAP, the manufacturer does not allow us to display our lowest price until you place the product in the shopping cart. This allows us to continue offering our lowest prices while staying consistent with product manufacturer's policy.

This process does not require you to purchase the product - it can be easily removed from shopping cart if needed.

Air separatorfunction

While PexUniverse.com reserves the legal right set its own product pricing, some manufacturers require internet retailers to display a price at or above manufacturer's established MAP ("Minimum Advertised Price").

When it comes to the potable water supply that the public utilizes, safety is the first priority. Vacuum breakers play an important part in that effort, and understanding when and where to use them and how they work can help maintain the highest level of safety.

The pressure type vacuum breaker evolved from the AVB. There are a number of AVB installation restrictions due to the limits of the design. One of the AVB's limitations is the restriction of no continuous water pressure. The concern of the inlet valve sticking closed is a serious one, as it would render the AVB useless. The PVB was designed to overcome this problem.

HVBs should be inspected and tested periodically to ensure they are working properly. Fortunately, their mode of operation permits inspections to be easily made. Verify the check valve closes and the atmospheric vent opens reliably whenever the water supply is shut off. It is very simple to do this if a nozzle that can be shut off is used on the end of the hose. When the nozzle shuts off, turn on the faucet and allow the hose to pressurize. Then, shut off the faucet while the hose is pressurized. After a few seconds, the hose pressure should be released in a small spray as the atmospheric vent suddenly opens.

In the plumbing world, the need to protect the potable water supply from the dangers that come from backflow and back siphonage is so well understood that to call it common knowledge would be a bit of an understatement. The 2015 Uniform Plumbing Code touches on the various methods to prevent backflow and backsiphonage in section 603.3, but diving a bit deeper could be useful.

Air separatorhow it works

The AVB has one moving part that works as an air inlet or port and it serves as a check valve to the supply piping when no water pressure is present. The PVB check valve is similar but spring loaded. When the piping-system pressure is reduced, the spring forces the check open to the atmosphere, allowing air into the system and breaking the downstream siphon.

This product does not meet the new low-lead criteria defined in Safe Drinking Water Act and cannot be used for potable water applications, including for drinking and cooking. This product can be used for non-potable water applications only.

An HVB prevents backflow to the water supply by venting water to the atmosphere (onto the ground) when backflow conditions exist. A spring-loaded check valve is opened by the water supply pressure when outflow occurs through the valve. When pressure is sufficient to open the check valve, flow is directed into the garden hose. When the supply pressure is interrupted or when the pressure in the hose becomes greater than the supply pressure, outflow stops and the spring-loaded check valve closes, simultaneously opening a vent to the atmosphere. In this mode of operation, any water that flows backward through the HVB is vented onto the ground.The spring-loaded check valve does not allow drainage of water from between the hose bibb and the upper part of the HVB; thus, freeze protection must be provided, just as all outdoor plumbing would need to be protected under freezing conditions.HVBs should be inspected and tested periodically to ensure they are working properly. Fortunately, their mode of operation permits inspections to be easily made. Verify the check valve closes and the atmospheric vent opens reliably whenever the water supply is shut off. It is very simple to do this if a nozzle that can be shut off is used on the end of the hose. When the nozzle shuts off, turn on the faucet and allow the hose to pressurize. Then, shut off the faucet while the hose is pressurized. After a few seconds, the hose pressure should be released in a small spray as the atmospheric vent suddenly opens.Pressure vacuum breakersThe pressure type vacuum breaker evolved from the AVB. There are a number of AVB installation restrictions due to the limits of the design. One of the AVB's limitations is the restriction of no continuous water pressure. The concern of the inlet valve sticking closed is a serious one, as it would render the AVB useless. The PVB was designed to overcome this problem.The AVB has one moving part that works as an air inlet or port and it serves as a check valve to the supply piping when no water pressure is present. The PVB check valve is similar but spring loaded. When the piping-system pressure is reduced, the spring forces the check open to the atmosphere, allowing air into the system and breaking the downstream siphon.

Air separatorvalve

When I was in college — more years ago than I would like to admit — I served as a resident assistant in my university's residence halls. Each floor had a vacuum students could use to clean their rooms. Despite the infrequency with which college students actually used the vacuums, it was amazing at how often they were broken. It turns out that the rubber band that spins the brush in the vacuum head is really no match to the vast cornucopia of odd items that young adults attempt to suck off their floors. Strands of long hair, socks, power cords, money, toilet paper, tin foil, as well as other "not safe for publication" items were all found to have disabled the economically priced vacuum cleaners provided for student use. At this time in my life, vacuum breakers would have held a completely different meaning to me than it does today after years of exposure to the plumbing industry.

The most basic form of protection is the presence of an air gap in between the possible source of contamination and access to the plumbing system, usually a plumbing fixture. However, other mechanical measures are often needed to guarantee this protection and understanding when exactly to use one method of protection or another is worth discussing. For this reason, we will discuss the other types of vacuum breakers — the ones that keep our drinking water safe.