Contaminant TreatmentSediment / Particulates:20 microns with a dirt holding capacity up to 2.2 lbs (1 kg)Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respects

WattsOneFlow Plusreviews

Water pressure reducing valves are devices used in plumbing systems to control and reduce the pressure of water flowing through pipes. They are installed where the incoming water pressure from the... Read More

The OneFlow®+ system is not a water softener. It doesnot add chemicals to the water. It is a scale prevention device with proven third party laboratory test data and years of successful residential installations. The OneFlow®+ system is the intelligent scale solution and is a great salt-free alternative to water softening (ion exchange) or scale sequestering devices.

One Flow water filter

Water pressure reducing valves can indirectly contribute to water conservation efforts. By reducing the water pressure to a more appropriate level, they can prevent wasteful water usage due to excessive pressure. Additionally, regulated pressure can improve the efficiency of fixtures and appliances, reducing water consumption.

While water pressure reducing valves generally require low-maintenance, it is recommended to have them inspected periodically. Sediment or debris in the water supply can affect the valve's operation, so it is important to clean or flush the valve if necessary. Additionally, the diaphragm or piston inside the valve may wear out over time and require replacement.

Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.

.Using OneFlow®+ System with Other Water Treatment EquipmentDue to the unique properties of OneFlow®+, there are some unique requirements for using OneFlow®+ in conjunction with filtration or other forms of water treatment.

NOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

WattsOneFlowFilter Replacement

The OneFlow®+ system is an economical and environmentally friendly physical water treatment technology that protects pipes, extends the life of appliances, and provides better tasting water through filtration. The OneFlow®+ system is a dual cartridge-based system with a radial flow 20 micron carbon block cartridge which reduces sediment, chlorine taste and odor, and an integrated OneFlow® scale prevention cartridge.

NOTICEThe replacement frequency listed above is maximum life expectancies. Filter replacement may be required sooner based on water quality and application variables.

Water pressure reducing valves are devices used in plumbing systems to control and reduce the pressure of water flowing through pipes. They are installed where the incoming water pressure from the municipal supply is too high and needs to be regulated to prevent damage to the plumbing system and appliances. Read Less

† OneFlow® media does not reduce silica scaling. While silica tends to have a less significant effect on scale formation than other minerals, it can act as a binder that makes water spots and scale residue outside the plumbing system difficult to remove. This 20 ppm limitation is for aesthetic purposes.†† All other contaminants must meet the requirements of the USEPA Safe Drinking Water Act. Specific Mineral and Metal MCL’s, identified in Watts published Feed Water Chemistry Requirements, supersedes the USEPA SDWA.Water known to have heavy loads of dirt and debris may require pre-filtration prior to OneFlow®.Filter Cartridge Replacement FrequencyFilter CartridgeReplacement FrequencyRadial Flow Carbon BlockReplace AnnuallyOneFlow® Scale Prevention CartridgeReplace Every 3 YearsNOTICEThe replacement frequency listed above is maximum life expectancies. Filter replacement may be required sooner based on water quality and application variables.NOTICE                                                                             pH6.5-8.5Hardness (maximum)30 grains (513 ppm CaCO3)*Water Pressure10psi to 90psi (0.69 bar to 6.2 bar)Temperature40°F to 100°F (5°C to 38°C)Free Chlorine<2 ppmIron (maximum)0.3 ppm**Manganese (maximum)0.05 ppm**Copper (maximum)1.3 ppm***Oil & H2SMust be Removed Prior to OneFlowTotal Phosphates<3.0 ppmSilica (maximum)20 ppm †TDS<1500 mg/L †† Contaminant TreatmentSediment / Particulates:20 microns with a dirt holding capacity up to 2.2 lbs (1 kg)Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

OneflowLogin

They are installed near the point of entry of the water supply, such as the main water line entering a building. This ensures that all water flowing into the plumbing system is regulated and the pressure is reduced uniformly throughout.

NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

* Systems using OneFlow® technology are effective at controlling lime-scale formation inside the plumbing system at influent hardness levels up to 30 grains per gallon (513 ppm) as calcium carbonate. Due to variances in water chemistry, 30 grains per gallon is a recommended hardness maximum due to potential aesthetic issues related to soft scale residue formation outside of the plumbing system. Testing should be performed to determine proper application where hardness levels exceed 30 grains per gallon.

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

** Just as with conventional water softening media, OneFlow® media needs to be protected from excess levels of certain metals that can easily coat the active surface, reducing its effectiveness over time. Public water supplies rarely, if ever, present a problem, but if the water supply is from a private well, confirm that the levels of iron (Fe) and manganese (Mn) are less than 0.3 ppm and 0.05 ppm, respectively.

Watts one Flow

Installing water pressure reducing valves in an irrigation system offers several benefits. They maintain optimal water pressure, preventing damage to sprinklers, emitters and other irrigation components. Additionally, they ensure uniform water distribution and reduce the risk of excessive water consumption. PRVs in irrigation systems also extend the lifespan of the system by minimising the strain on pipes and reducing the potential for leaks.

Watts one flow review

The overall height and the height of the inlet fitting varies due to material variations and assembly tolerances. Please allow additional clearance above the system for making connections and replacing cartridge filters.Feed Water Chemistry RequirementspH6.5-8.5Hardness (maximum)30 grains (513 ppm CaCO3)*Water Pressure10psi to 90psi (0.69 bar to 6.2 bar)Temperature40°F to 100°F (5°C to 38°C)Free Chlorine<2 ppmIron (maximum)0.3 ppm**Manganese (maximum)0.05 ppm**Copper (maximum)1.3 ppm***Oil & H2SMust be Removed Prior to OneFlowTotal Phosphates<3.0 ppmSilica (maximum)20 ppm †TDS  NOTICE* Systems using OneFlow® technology are effective at controlling lime-scale formation inside the plumbing system at influent hardness levels up to 30 grains per gallon (513 ppm) as calcium carbonate. Due to variances in water chemistry, 30 grains per gallon is a recommended hardness maximum due to potential aesthetic issues related to soft scale residue formation outside of the plumbing system. Testing should be performed to determine proper application where hardness levels exceed 30 grains per gallon.** Just as with conventional water softening media, OneFlow® media needs to be protected from excess levels of certain metals that can easily coat the active surface, reducing its effectiveness over time. Public water supplies rarely, if ever, present a problem, but if the water supply is from a private well, confirm that the levels of iron (Fe) and manganese (Mn) are less than 0.3 ppm and 0.05 ppm, respectively.WARNING*** Pursuant to the EPA drinking water standards, the copper concentration permitted is up to 1.3 ppm. Typically originating from new copper plumbing, high levels of copper can foul OneFlow® media. New Copper lines need to be passivated for a minimum of 4 weeks before placing the unit into service. For applications with copper concentrations greater than 1.3 ppm, please consult Watts Water Quality Technical Service. To further minimize any problem with excess copper, avoid applying excessive flux on the inner surfaces of the pipe and use a low-corrosivity water-soluble flux listed under the ASTM B813 standard.NOTICE† OneFlow® media does not reduce silica scaling. While silica tends to have a less significant effect on scale formation than other minerals, it can act as a binder that makes water spots and scale residue outside the plumbing system difficult to remove. This 20 ppm limitation is for aesthetic purposes.†† All other contaminants must meet the requirements of the USEPA Safe Drinking Water Act. Specific Mineral and Metal MCL’s, identified in Watts published Feed Water Chemistry Requirements, supersedes the USEPA SDWA.Water known to have heavy loads of dirt and debris may require pre-filtration prior to OneFlow®.Filter Cartridge Replacement FrequencyFilter CartridgeReplacement FrequencyRadial Flow Carbon BlockReplace AnnuallyOneFlow® Scale Prevention CartridgeReplace Every 3 YearsNOTICEThe replacement frequency listed above is maximum life expectancies. Filter replacement may be required sooner based on water quality and application variables.NOTICE                                                                             pH6.5-8.5Hardness (maximum)30 grains (513 ppm CaCO3)*Water Pressure10psi to 90psi (0.69 bar to 6.2 bar)Temperature40°F to 100°F (5°C to 38°C)Free Chlorine<2 ppmIron (maximum)0.3 ppm**Manganese (maximum)0.05 ppm**Copper (maximum)1.3 ppm***Oil & H2SMust be Removed Prior to OneFlowTotal Phosphates<3.0 ppmSilica (maximum)20 ppm †TDS<1500 mg/L †† Contaminant TreatmentSediment / Particulates:20 microns with a dirt holding capacity up to 2.2 lbs (1 kg)Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

Your OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:

Watts OneFlow®+ systems are complete, self-contained, loaded with media and ready to use. A simple inlet and outlet connection is all that is required for installation. Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility and performance.

The new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residential

Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

One flow media

Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.

NOTICE                                                                             pH6.5-8.5Hardness (maximum)30 grains (513 ppm CaCO3)*Water Pressure10psi to 90psi (0.69 bar to 6.2 bar)Temperature40°F to 100°F (5°C to 38°C)Free Chlorine<2 ppmIron (maximum)0.3 ppm**Manganese (maximum)0.05 ppm**Copper (maximum)1.3 ppm***Oil & H2SMust be Removed Prior to OneFlowTotal Phosphates<3.0 ppmSilica (maximum)20 ppm †TDS<1500 mg/L †† Contaminant TreatmentSediment / Particulates:20 microns with a dirt holding capacity up to 2.2 lbs (1 kg)Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.

The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.

The OneFlow®+ system uses template assisted crystallization to attract dissolved hardness minerals and convert them into harmless, inactive microscopic crystal particles.

These crystals stay suspended in the water and have a greatly reduced ability to react and attach to surfaces like dissolved hardness does. They eventually find their wayto a drain. The system requires very little maintenance, no backwashing, no salt and no electricity.

Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

Yes, water pressure reducing valves restrict the flow of water to some extent as they regulate the pressure. However, they are designed to maintain a steady and consistent flow while reducing the pressure.

Unpack and check the system components for damage or missing parts.Installation ConsiderationsConsider the following points when determining where to install the system:

Water hammer is a hydraulic shock that occurs when water flow is suddenly halted or changed in direction, resulting in loud banging noises in pipes. While water pressure reducing valves can mitigate water hammer to some extent by regulating the pressure. Additional measures, such as installing check and foot valves may be required to effectively control the water hammer.

WattsOneFlowanti scale system

*** Pursuant to the EPA drinking water standards, the copper concentration permitted is up to 1.3 ppm. Typically originating from new copper plumbing, high levels of copper can foul OneFlow® media. New Copper lines need to be passivated for a minimum of 4 weeks before placing the unit into service. For applications with copper concentrations greater than 1.3 ppm, please consult Watts Water Quality Technical Service. To further minimize any problem with excess copper, avoid applying excessive flux on the inner surfaces of the pipe and use a low-corrosivity water-soluble flux listed under the ASTM B813 standard.

Water pressure reducing valves are necessary when the incoming water pressure from the municipal supply is too high. High water pressure can damage pipes, fixtures and appliances, leading to leaks, bursts and other plumbing issues. These valves regulate and reduce the pressure to a safe and manageable level, protecting your plumbing system.

Raptor Supplies offers a wide range of water pressure reducing valves or regulators designed to control the influx of water supply pressure and reduce it, from brands like Apollo, Watts, Bell & Gossett, Taco, Wilkins and Cash Acme. These water pressure reducing valves are ideal for house plumbing lines, pipe fittings and low pressure pipelines. Apollo 36ELF, 36H, 36 HLF and 36LF Series valves feature low lead or lead free bronze construction with a stainless-steel adjusting screw and dielectric cage for superior corrosion resistance. The pressure ranges between 15 and 75 PSI. These Apollo valves have FNPT connections and are designed according to ASSE and CSA standards for ensuring reliable operation. They are available in 1/2 inch to 3 inch pipe sizes. Watts offers pressure reducing valves in iron, bronze, lead free brass, lead free copper and lead free copper silicon variants for valves with pressure ranging between 3 and 140 PSI. 152A Series steam pressure regulators by Watts are used in oil lines, autoclaves, steam irons and single radiators. These steam regulators provide highly sensitive pressure response with minimal pressure drop. These 152A Series valves feature FNPT threaded inlet and outlet ports for pipe sizes up to 1 inch in diameter.

NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

Sediment / Particulates:20 microns with a dirt holding capacity up to 2.2 lbs (1 kg)Chlorine Reduction:50,000 gallons (189,000 liters)† @ 3 gpm (11.34 lpm)Scale Prevention: Up to 3 years † according to lab test of carbon block manufacturerCAUTIONDo not let the system freeze. Damage to the housing may result.System must be operated in a vertical position. Do not lay it down during operation. The system may be placed in any position for shipping and installation but must be operated in the vertical position.Place the system on a smooth, level surface. Because the system operates in an UP-Flow, fluidized bed mode, having a level surface is more important than with a softener or media filter.A bypass valve should be installed on every system to facilitate installation and service.Observe all local plumbing and building codes when installing the system.All new copper pipe and fittings used in the installationof this system should be allowed to self passivate, under normal operation and water flow, for a period of 4 weeks minimum before placing the unit into service.If making a soldered copper installation, do all sweat soldering before connecting pipes to the system’s threaded inlet and outlet plastic plumbing adapters. Torch heat will damage plastic parts.When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.Use PTFE tape on all external pipe threads. Do not use pipe joint compound.The complete weight of the plumbing system must be supported by pipe hangars or other means.Do not use on water that is microbiologically unsafe or of unknown quality.NOTICENotes to the InstallerThe OneFlow®+ system differs from a conventional softener or media filter in a number of key respectsThe system is light and only partially filled with media. This is normal. The UP-flow operation of the system requires a lot of freeboard to allow the bed to fully fluidize.The system has no underbed so you can tip the system over without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems. System must be installed in VERTICAL POSITION.Please observe all Feed Water Chemistry Requirements and all related NOTICES and WARNINGS on page 3.Please see the note about “Using OneFlow®+ System with Other Water Treatment Equipment” on page 2.This system is designed for residential applications only.Installation InstructionsThe new system comes with the cartridges and outlet connector pre-installed. The installer should verify this prior to installation.How to install your OneFlow®+ system can also be found at: http://thescalesolution.com/residentialNOTICEPlease remove all items from the carton. Confirm that all items are present and ready for assembly and installation.The system can stand upright in the desired location without the need to affix to a wall with a mounting bracket. However, a mounting bracket is included as a separate part (Item 1).Place the system in the desired location. Make sure that the location is level and sturdy enough to support the weight of the system when in operation.Turn off the main water supply to the home and open an inside faucet to relieve any pressure within the plumbing system.Apply plumbing tape to the threads of the 1″ NPT Threaded Adapters(Item 3) and insert them into the inlet and outlet of the OneFlow®+ Housing (Item 2) as shown in Diagram A.Secure these adapters with the two red adapter Locking Pins (Item 4) as shown in Diagram A.Connect the cold water supply to the inlet of the OneFlow®+ system.Install a supply valve (user supplied) in the supply line and close it.Place a bucket under the outlet port or run a line from the outlet port to a drain.Turn on the main water supply to the home. Slightly open the supply valve to the OneFlow®+ system to allow the housing to fill with water. Close the supply valve when a steady stream of water comes out of the outlet port. If the outlet is flowing into a bucket, water could splash on nearby objects. If this threatens the safety, value, structure, or appear-ance of these objects, protect/remove them or use the outlet hose to drain option.Close the inside faucet.Connect the outlet of the OneFlow®+ system to the cold water supply to the house.Install an outlet valve (user supplied) in this plumbing line and close it.Install and optional bypass valve between the inlet and outlet plumbing lines and close it.Open the inlet and outlet valves and both the hot and cold faucets downstream from the OneFlow®+ system to relieve any air from the plumbing system and water heaters. Then close the faucets.Check for leaks. Repair as needed.Changing the Filter Cartridges:Turn off the inlet and outlet valves on the system’s supply and outlet lines.Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve(Item 5) – refer Diagram F.Use Multifunction Tool (Item 6) to unscrew OneFlow®+ Head Assembly (Item 7) counterclockwise and remove from the OneFlow®+ Housing as shown in Diagram G.Remove Outlet Connector (Item 8) from top of OneFlow®+ Scale Reduction (TAC) Cartridge – refer Diagram D.Use Multifunction Tool (Item 6) to remove OneFlow®+ Scale reduction (TAC) cartridge (Item 10) from the Sediment/Carbon Cartridge (Item 9) as shown in Diagram H.Remove the Sediment/Carbon (Item 9) from the OneFlow®+ Housing by hand.Remove new Sediment/Carbon cartridge from packaging and place carefully inside the OneFlow®+ Housing as shown in Diagram B.Insert OneFlow®+ Scale Reduction (TAC) cartridge back into the center of the Sediment/Carbon cartridge making sure that it is sealed correctly as shown in Diagram C.Insert Outlet Connector (Item 8) into outlet port and secure back on top of the OneFlow®+ Scale Reduction cartridge as shown in Diagram D.Place Head Assembly back onto OneFlow®+ Housing and using the multifunction tool tighten by screwing the Head Assembly clockwise as shown in DiagramDO NOT OVERTIGHTEN. Close the pressure relief valve by tightening in a counterclockwise direction as shown in Diagram F.Turn on the inlet and outlet valves on the system’s supply and outlet lines and check for leaks.Open a downstream cold water faucet to flush any air from the plumbing system.NOTICEWhere influent water pressure will at any time exceed 500 kPa (70psi) a suitable pressure limiting valve must be installed.Product performance is dependent upon influent water quality.The system must be installed and maintained in accordance with the manufacturer’s instructions including replacement of the filter cartridges.Please ensure all O-rings are well lubricated and clean from foreign particles.Note To The Home OwnerYour OneFlow®+ system will improve the properties of water throughout your home. Here are some things to expect and some recommendations for maximizing the benefits and your enjoyment of OneFlow+:Sinks and fixtures – should have reduced spotting. If water is allowed to evaporate off a surface, small spots may be left behind. Many times this residue is easier to clean up than the previous hard water spotting.Dishwasher-Spotting on dishes and on the surface of the dishwasher should be greatly reduced.We recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to hard wateruse. Dishwashing detergents low in phosphates are highly recommended as they are better for the environment and phosphates can cause spotting. In very hard water areas, the use of rinse aid may be advised. Shower doors and tiles – should have reduced spotting. When water evaporates off a surface, small spots may be left behind. Depending on water chemistry, these spots may be easy to remove with a damp cloth or sponge..In the bath Soaps and shampoos will rinse off much easier and faster than they would with traditional soft water. We recommend the use of modern soaps for the best results.Things to watch for:During the first 30-90 days:Faucet aerators and drains may plug occasionally as old scale is removed from your plumbing system and water heater.You may also see milky water after installation of the system. This could be due to trapped air within the plumbing system or the descaling affect of OneFlow® and will eventually go away.Good practices:If your dishwasher is severely coated with scale at the time of installation, we recommend that you purchase a product like Jet-Dry® Dishwasher cleaner to accelerate the cleaning. After this initial cleaning OneFlow®+ should keep it clean.We also recommend that you drain your water heater tank. This should be done 30 to 60 days after OneFlow®+ is installed, and again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow®+ will help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturer’s instructions when draining the tank!Ordering InformationONEFLOW®+ COMPLETE SYSTEMOrdering CodeModel NumberDescription7100638OFPSYSScale Prevention and Water Filter SystemONEFLOW®+ WATER FILTER REPLACEMENT7100639OFPRFCRadial Flow Carbon Block Cartridge7100640OFPSPScale Prevention Cartridge7100641OFPCOMScale Prevention and Carbon Block Combo PackONEFLOW®+ SYSTEM REPLACEMENT PARTS7300759OFPHSGHousing and Head Assembly7300760OFPAPInlet/Outet Red Adapter Locking Pin7300761OFPA1-In NPT Inlet/Outlet Adapter7300762OFPOCOutlet Connector7300763OFPTOOLMultifunction Tool7300764OFPMBSystem Mounting BracketLimited WarrantyThe OneFlow®+ cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment.The OneFlow®+ cartridge is warranted for performance for a period of 2 years from the date of the original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.ConditionsOneFlow®+ systems are warranted for domestic use in residential single family dwelling applications excluding irrigation water treatment. The use of these systems in light commercial, commercial, or industrial applications will void their limited warranty.The OneFlow®+ system must be installed in applications with municipally supplied water adhering to EPA guidelines.Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.(Please contact your water treatment specialist.)Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made.Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then-current production.LimitationsOur obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.Our obligation under this warranty with respect to the OneFlow®+ media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty.THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,or any other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights.SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.Documents / ResourcesWATTS OFPSYS OneFlow+ Salt-Free Scale Prevention and Water Filtration System [pdf] User ManualOFPSYS, OneFlow Salt-Free Scale Prevention and Water Filtration SystemReferencesUser ManualRelated PostsJENSEN JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada User ManualJCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador…KORG Sound Link User GuideSound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Guía de inicio rápido Puede descargar el Manual del usuario en…jura 583W Cool Control 1 l Advanced Cool Control Instruction Manual_pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1…STRONG SRT 82 Terrestrial HDMI Receiver For TV User ManualSRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User…

Signs that you may need a pressure reducing valve include excessively high water pressure, frequent leaks or bursts in your plumbing system, banging noises in pipes and inconsistent water flow.

This website is an independent publication and is neither affiliated with nor endorsed by any of the trademark owners. The "Bluetooth®" word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. The "Wi-Fi®" word mark and logos are registered trademarks owned by the Wi-Fi Alliance. Any use of these marks on this website does not imply any affiliation with or endorsement.