Solenoidvalve

We take pride in supplying, Made in the USA, products that serve as our customers’ last line of defense. But we do not stop there. Our engineers and technicians work tirelessly to explore new ways to improve the safety, reliability, and longevity of our safety relief valves, decreasing the cost of ownership. Mercer Valve is a company you can trust to keep you safe and protected.

Double check valves (DCV, also called double check assemblies or DCA) are a good choice for underground or indoor installations. A DCA consists of an inlet shutoff valve, two independently operating spring-loaded check valves (usually inside a single valve body), four test cocks, and an outlet shutoff valve. If local building codes allow for it, you must install Double check assemblies vertically.

pressurereliefvalve中文

Several factors must be taken into consideration when selecting a backflow device. These include local building codes regulating backflow preventers, the size of the landscape to be irrigated, and where the backflow preventer is going to be installed. It’s a good idea to familiarize yourself with the different types of backflow devices. It will help you to select the one that best meets your requirements.

At Mercer Valve, we are committed to providing high-quality, unmatched service and repair, delivered on time for our customers. Our team of skilled technicians delivers reliable solutions for all your needs, offering service and repairs for all valve brands, on-site and mobile services, training, and compliance with DOT and our customers’ OQ requirements.

Pressurevalve

Reduced pressure zone assemblies come in a variety of configurations. Choose an “inline” or “straight” configuration for installation underground. For above-ground installation, consider an “n” configuration assembly for a very small footprint.

One of the downsides of PVBs is that they will occasionally eject some water. Choose a “spill-resistant” model of PVB for indoor installations or any time spillage would create a nuisance. An air gap drain is also required if the valve is installed in a basement or other interior space.

Checkvalve

Mercer Valve is a mixed-mode manufacturer committed to providing high-quality, long-lasting pressure relief valves that distributors, manufacturers, and families can depend on every day. We take safety seriously and prioritize it in everything we do, from the engineering and production of our valves, to their service and repair. Trust us to deliver powerful solutions that keep you safe.

Pressure vacuum breaker assemblies (PVB) are the most common, inexpensive type of whole-system backflow preventer. It consists of an inlet shutoff valve at the bottom, a single valve body consisting of a pressure vacuum breaker, a check valve, two test cocks, and an outlet shutoff valve. As well as being inexpensive, PVBs are relatively simple in design and are easy to install, maintain and repair. Some pressure vacuum breakers also offer built-in freeze protection; however, this only protects the PVB assembly. Inlet and outlet pipes can still freeze if the system isn’t properly winterized.

We enjoy the partnership we have forged with Mercer and appreciate their level of customer support. Mike Fravert ARCO Engineering Kentucky

Over the last ten years, we have not had one single complaint regarding valve failure. Jim Bedford QC Pumps & Compressors, Ltd. New Brunswick

The image above shows the Febco 825Y Reduced Pressure Zone Backflow Preventer. Shop for this and other backflow preventers at SprinklerWarehouse.com.

reliefvalve中文

Image

As members of the Mercer Valve family, we are dedicated to safety. With the best interests of our communities in mind, from design to distribution we take exceptional care to ensure the safety and integrity of our people, products, and operations. We believe that in addition to long-lasting pressure relief valves, the most valuable product we provide is peace of mind.

Reduced pressure zone assemblies (RPZ), also sometimes called a reduced pressure principle assembly, is the most complex and expensive backflow preventer. However, when working properly, RPZs are the most secure and reliable of all backflow prevention devices. A reduced pressure zone assembly consists of an inlet shutoff valve, two independently operating spring-loaded check valves separated by a pressure differential relief valve, four test cocks, and an outlet shutoff valve.

Valves

There are multiple types of backflow preventers. The three most common are the pressure vacuum breaker (PVB), the reduced pressure zone (RPZ), and the double check assembly (DCA). These are all installed in the water system immediately after the isolation valve. There is a fourth backflow preventer which is also fairly common. The atmospheric vacuum breaker (AVB) is installed in each zone of the sprinkler system. After that, it immediately follows the zone control valve. Each type of backflow device is designed to provide a different level of protection for varying commercial or residential applications. For example, hospitals and morgues, which handle large quantities of hazardous wastes on a daily basis, require much heavier-duty backflow preventers than a residential irrigation system.

Safetyvalve

Image

AVBs are also the least reliable and least often recommended. Most large cities and suburbs do not allow the use of atmospheric vacuum breakers in lawn sprinkler systems. Do not use AVBs in areas of constant pressure. This includes where shutoff valves would be located downstream where there is a potential for back pressure, or on any system that incorporates chemigation techniques.

Installed either above ground or inline (underground) Do not use with chemigation May be installed horizontally or vertically, but horizontally is preferred May be installed where the potential for back-siphonage or backpressure is present.

Pressurerelief valve

It is possible to build a double check valve assembly from new components, but this is not the best option as there is a high risk of built assemblies not meeting local code. A better option, for convenience, cost-effectiveness, and coding restrictions, is to purchase a pre-assembled double check valve assembly.

Image

The DCA is the most common type of approved backflow prevention device for use in underground or in-line installations. In-line (or below-grade) simply means that the backflow device is parallel with the piping of the sprinkler system; unlike the PVB, the DCA does not have to be installed 12 inches above the highest point in the system. Some areas do require above-ground installation, so check with local authorities before installing below ground.

Some localities, such as Honolulu, do not allow reduced pressure zone assemblies to be installed below grade in underground lawn sprinkler systems, while others require copper pipes on both ends of the assembly. Local codes may be especially variable and stringent on reduced pressure zone assembly, so have a thorough understanding of local requirements before proceeding.

Atmospheric vacuum breakers (AVB) are the simplest and least expensive backflow preventers for one or two-zone irrigation systems. An AVB must be installed on the pipe directly after every control valve, so for systems with more than about six control valves, AVBs are not cost-effective.