When selecting a pressure tank, remember that the stored water volume in it is, on average, 40-50% of the tank's total volume.

The second calculation option for the pressure tank prioritizes the stored water volume. It is recommended for systems where water supply interruptions are not allowed, but there are power outages or interruptions in the centralized water supply.

WattsPremierFilter replacement instructions

The activation frequency is related to the pump's electric power. For example, pumps with a power of more than 8 kW should be activated no more than 10 times per hour, pumps with a power of less than 5 kW – no more than 20 times per hour, and pumps in the range of 5 to 10 kW should be activated slightly more than 15 times per hour. This dependence is the basis of the calculation algorithm above.

The maximum water pressure Pmax is typically not more than 4.5 bar, and in some cases, 6 bar. As a minimum, Pmin is the pressure at which the excess pressure at the top faucet is the minimum allowable value, usually (0.2-1.0 bar).

Image

Wattspremier Reverse Osmosisdiagram

PremierRO Pure Plus Filters

The first calculation option for the pressure tank prioritizes pump activation frequency. In systems with booster stations, well pumps, and booster pumps, a pressure tank is required to reduce the frequency of pump activation.

Water cannot be compressed like air due to its physical properties. Therefore, even a short-term opening of one faucet in a multi-apartment building can cause the pump to turn on. Frequent pump activation leads to rapid wear and breakdown.

Since 1977 we've become a premier distributor and supplier of drinking water filter and purification products, whole home water treatment systems, decorative plumbing and luxury appliances.

When selecting a pressure tank, consider its temperature and strength characteristics. The maximum tank pressure must be equal to or greater than the maximum pressure at the connection point.

WattsPremierWP-5Manual

premierro-pure plusmanual

If the installation of pressure tanks is planned indoors, keep in mind that tanks with a diameter larger than 750 mm and a height greater than 1.5 m may not fit through the doors, and mechanized means may be required for transportation. In this case, it is better to opt for several smaller pressure tanks instead of one large one.

WattsPremier Reverse Osmosis

Image

Before connecting to the water supply system, it is necessary to set the gas space pressure in the pressure tank Pg (inflate the tank) according to the value provided in the calculation results. To do this, it may be necessary to release pressure through the valve or inflate the tank with a compressor, depending on the factory-set gas space pressure. After setting the gas space pressure, connect the tank to the water supply system.

We are gathering a community of experts in the design, installation, and service of heating, hot water, and water supply systems in Australia. Join the community and you will receive emails with requests for work in Australia from our visitors.

The selected pressure tank volume should be equal to or greater than the volume obtained from the calculation. There are no negative consequences of oversizing the pressure tank, regardless of how much the volume exceeds the calculated value.

Premier Reverse Osmosisfilters

In addition to pump power, many other factors influence the allowable activation frequency, such as the mass of moving parts. The larger the mass, the lower the allowable activation frequency. Therefore, pay attention to the match between the activation frequency values obtained from the pressure tank selection and the optimal frequency for the selected pump, and if necessary, recalculate the tank.

JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.

In water supply systems, pressure tanks solve many tasks, and calculations for each case are performed using different methodologies. The algorithm above allows you to select tanks for two of the most popular tasks and determine the initial gas space pressure, pump activation, and deactivation pressures.