25AUB-Z3 / N35B Both units - are bronze, have removable strainer, seat, and have the bypass feature. The design difference allows the 25AUB-Z3 to have a higher flow rate than the N35B. Properly sized, either unit should work fine for your residence. Even though these units have a bypass you should still have an expansion tank on your hot water distribution system.

I think I understand, thanks! One last question. Do you think it's worth for me to be able to clean out the strainer? I'm on city water.

Image

Can someone tell me the advantages between the 25AUB-Z3 and the N35B Watts pressure reducing valves? Which one should I get? The 25AUB-Z3 valve seems to be about 15 bucks more expensive. [www.wattsregulator.com]

Since 1910 Ames Fire & Waterworks has been a leader in the manufacture of valves and fittings for all types of pipeline systems. Ames products serve the fire protection, irrigation and waterworks markets and have a reputation of excellence in the industry. Ames production process promotes consistent quality control and prompt customer service. If excellence matters to you, then specify Ames.

Welcome to Plbg.com (also known as PlumbingForum.com) where plumbing advice, education, information, help and suggestions are provided by some of the most experienced plumbers and plumbing contractors anywhere who all wish to "give back" to society. Since 1996 we have been free without popup or other invasive ads and known to be the best online STRICTLY PLUMBING advice site. If you have questions about plumbing, toilets, sinks, faucets, drains, sewers, water filters, venting, water heating, showers, pumps, and other strictly PLUMBING related issues then you've come to the right place. Please refrain from asking or discussing legal questions, or pricing, or where to find and/or purchase products, or any business issues, or for contractor referrals, or any other questions or issues not specifically related to plumbing. Keep all posts positive and absolutely no advertising. Our site is completely free, without ads or pop-ups and we don't track you. We absolutely do not sell your personal information. We are made possible by:

Image

I get it, the size range for the 25AUB-Z3 is 1/2" to 2" and for the N35B it's 1/2" to 1". Thanks! Your answer makes alot of sense.

These are the same type of device; different bells and whistles. The N35B has an bypass feature and 'cartridge' type seat assembly for easy repair. The other model has a strainer which can be easily accessed for periodic cleaning. Both are widely seen in residential use, as are the Wilkins model 70 and model 600.

Image

Sorry, I guess I'm really confused. The discription for the N35B & 25AUB both say they are "Water Pressure Reducing Valves" and "consists of a bronze body construction". What is the difference between a water pressure regulator and a water pressure reducing valve??? I want to reduce the pressure comining into my house which is now at 100PSI.

The 25AUB, is a bronze body water pressure regulator The N35B is a water pressure reducing valve both are set at the factory for 50 lbs. You really have to know your needs before making a choice. Best Wishes