It is also important to test your Temperature and Pressure Valve to be sure it is working properly and that the valve discharge is to an area that will not cause property damage or personal injury. Please refer to the water heater manual or a licensed plumber to determine how to test the Temperature and Pressure Valve.
Pressure Regulator Valve, NPT Threaded Female Union Inlet x NPT Female Outlet Connection, Ambient Temperature: 160 Deg F, Maximum Inlet Pressure: 300 psi, 1-1/4 inch Pipe, Standards: ASSE, CSA Certified, UPC Listed, Includes Strainer, For Use With: Plumbing System
Thank you for contacting Mobile Area Water & Sewer System. To connect you with a live agent, please choose whether you need assistance with an account issue or an emergency.
lf25aub-z3 1
When water is heated in a tank-type water heater, it expands. Before the dual check valve was installed, this water flowed back towards the public water supply. With a dual check valve in place, water stays on the customer’s side of the meter which can increase pressure. If the pressure is more than your plumbing system can handle, it could set off the temperature and pressure valve (T&P Valve) on your hot water heater, causing it to leak. There is also the possibility of it causing damage to the water heater, pipes or other fixtures (See illustration beow).
In the interest of public safety and security of the water supply, the Alabama Department of Environmental Management now requires MAWSS to install a backflow prevention device or dual check valve, on the customer’s side of the meter whenever the water service line and meter are replaced. This may require some changes to your plumbing system.
A Temperature and Pressure Valve alone is not adequate to address thermal expansion on a continuing basis. Mobile’s Plumbing Code requires that additional devices be installed, such as a one gallon thermal expansion tank or a pressure relief valve that discharges to the outside of the building. Contact a licensed plumber or the City Plumbing Inspection Department to get details on how best to protect your plumbing.
lf25aub-z3 3/4
When a dual check valve is installed on your water service line, water is unable to flow back into the public water supply. This creates a closed system in your water plumbing and can result in a spike in pressure, also known as thermal expansion.
Series LF25AUB-Z3 water pressure reducing valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is suitable for water supply pressures up to 300 psi (20.7 bar) and may be adjusted from 25 to 75 psi. The LF25AUB-Z3 features Lead Free* construction to comply with Lead Free* installation requirements. The standard setting is 50 psi (345 kPa). All parts are quickly and easily serviceable without removing the valve from the line. The standard bypass feature permits the flow of water back through the valve into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main supply.