When a flow stop occurs, both check valves close. At that moment, the relief valve opens and evacuates the water between the valves. (Figure 3) Some think that this event defines the limit of how much water can ever flow from the RPZ into a drain. This is not so.

How do you determine hazard? The simple answer is that the purveyor determines it, but every jurisdiction is different. Every city has its own list of named examples for what constitutes the hazard threshold. Here is an example from Washington DC. They also stipulate that if the anticipated use, as you know it, is not named explicitly, then they reserve the right to make the decision during plans review. It’s also important to understand that you cannot, as a designer, over-protect the incoming water service. This means there is no penalty for providing the higher degree of protection.

Consider a flow-stop situation, like one that might naturally occur at the end of the day (Figure 4). If you look closely, you can see that a small pebble has lodged in the #2 check valve. Now imagine some sort of back siphon event over night. Perhaps a nearby building fire leaches the water back with the draw of a fire hydrant; or a pump station fails; or a water main breaks. Because the #2 check valve is not closing, all the water that has been delivered to the building will continue to flow out the relief valve until the private lines are cleared. If this is a four story building, that’s a lot of water.

WattsBackflow preventer

Part No. Size Case Carton Weight (lbs) 701-503G 1/2" 100 10 52 701-504G 3/4" 60 10 50 701-505G 1" 40 5 53 Meets ANSI B16.39 ANSI B1.20.1 ASME/ANSI B16.18 ...

FEBCO

Image

210-21 Altitude Rate-of-Flow Control Valve - 210-21 Altitude Rate-of-Flow Control Valve.

Through partnerships with organizations such as Habitat for Humanity International, Infiltrator’s product donations assist projects across the US.

Series LF009 reduced pressure valve assembly backflow preventers are designed to prevent the reverse flow of liquids in a plumbing system due to backpressure ...

The Reduced Pressure Zone Valve Assembly (Figure 2) consists of two independently operating check valves just like the Double-Check as well as a hydraulically operated differential relief valve located below the first check valve.

backflowpreventer中文

Now consider a full failure of the #2 check valve, like one that might occur if the device is knocked out of round or has a mechanical failure. It’s essentially the same event with the exception that due to the larger valve opening, there is actually a higher flood rate. Now you have water flowing through the relief valve at full head pressure. Again, if this is a large or multi-story building, that’s a lot of water very fast.

Your Infiltrator Customer Account Specialist works closely with you and your Area Sales Representative to coordinate the orders and shipments you receive from us. This team is split up by product line and each individual covers a given territory so you will work with a consistent person. Let's meet the team!

The Double-Check Assembly (Figure 1) was developed in the 1950s for the fire industry. Any time the pressure on the property (downstream) side exceeds the pressure on the city (public) side, the two redundant check valves close stopping the backwards water flow. There are two problems with the Double-Check backflow preventer. First, no remedy exists in the event of a malfunction of the valve closures or if debris in the water line causes the valves to not close completely. Second, and this is the big problem, there is no way to know when such a failure has occurred without conducting a full test by a qualified professional.  The Double-Check is a closed system. It has no method of revealing whether the internal check valves are functioning properly and no way to detect the presence of debris that is impeding full closure.

2024530 — The new ALPHA HWR and ALPHA COMFORT SYSTEM recirculation pumps offer components that communicate digitally, eliminating wasted time finding the right pump ...

Have a question about a backflow preventer enclosure?Click the contact us button below and one of our experts will be able to help with your specific enclosure needs.

You’ve heard these phrases and acronyms repeatedly. If you are a designer, you feel sure that you are expected to know what they mean. Here’s a quick rundown on what they are and how they differ.

HILLIARD, Ohio – (August 20, 2024) – Advanced Drainage Systems, Inc. (NYSE: WMS) (“ADS” or the “Company”), a leading provider of innovative water management solutions in the stormwater and onsite septic wastewater industries, today announced the signing of a definitive agreement pursuant to which the Company’s wholly-owned subsidiary, Infiltrator Water Technologies (“Infiltrator”), will acquire Orenco Systems, Inc. (“Orenco”), a leading manufacturer of advanced onsite septic wastewater treatment products serving residential and non-residential end markets. The parties expect the transaction to close in the Company’s third quarter of fiscal 2025, subject to customary closing conditions.

A designer may specify one of 2 types of backflow prevention devices. First, the Double-Check Valve Assembly. This is often shortened to DC and is typically thought of as the appropriate solution for low hazard conditions. Second, the Reduced Pressure Zone Valve Assembly, often shortened to RP or RPZ, is thought of as the appropriate solution for high hazard conditions.

Monday to Thursday from 8:30 a.m. to 1:30 p.m. and from 3:00 p.m. to 6:00 p.m. Friday from 8:00 a.m. to 4:00 p.m..

MaxLine® Tempering Valve. RETIRED. Model 7-210-CK-D. Maxline thermostatic mixing valve; 3/8" compression connection; ASSE 1017/1070, CSA B125.3 certified; Lead ...

Infiltrator Water Technologies has been a market leader within the onsite wastewater treatment industry for over 35 years. Infiltrator manufactures a full line of innovative products for decentralized wastewater treatment. Our decentralized wastewater solutions include environmentally friendly alternatives to traditional stone and pipe leachfield and concrete septic system components as well as advanced wastewater treatment units and combined treatment and dispersal systems. We sell our products through wholesale distribution across the United States and Canada for use on properties with onsite wastewater treatment systems.

FEBCO 825Y 3/4" - 1 1/4" RELIEF VALVE COVER. Your Price: $102.24. 101-029. Part Number: 1113. Availability: In Stock. Put me on the Waiting List.

WATTS 0009257 is a Pressure Reducing Valve with 3/4" FNPT Union x FNPT ends, rated for 25 to 75 psi. See full Watts LF25AUB-Z3 specs and buy now.

Backwater valve

The Zone Valve Control 306V connects up to six thermostats and operates zone valves to provide heating to a zoned hydronic heating system. The 306V operates a ...

This hydraulic valve and its placement makes the RPZ virtually fail-safe but it comes at a cost to the area around the device.

Watch the video below for an example of RPZ flooding and to see just how much water is discharged when a small amount of debris becomes lodged in the device.

Check valve

ADS Recycling, a subsidiary of Infiltrator Water Technologies, is a leader in the use of “green materials” including post-consumer and post-industrial recycled plastics for the manufacture of products at its ISO 9001-registered manufacturing facility in Winchester, KY.

Tekmar Thermostat 561 Tekmar 562 Tekmar 532 Tekmar 552 Tekmar 553 Tekmar 554 Tekmar 557 Tekmar 519 Tekmar Thermostats Tekmar 507 Tekmar 508 Tekmar 509 ...

The main thing to take away from this is that both backflow prevention device types perform the same function when they are operating properly, but only the RPZ is designed to protect the public water supply by disposing of any backwards-flowing water if any of the check valves or the relief valve fails.