Balancing valvefor hot water return

The Febco 765 is a popular choice for protecting against backflow in residential and commercial applications, but like any mechanical device, it can experience wear and tear.

Recirculating domestic hot water systems (DHWS) distribute hot water to point-of-use fixtures throughout a building. DHWS are typically used in facilities with a high capacity of people, like hotels, hospitals, schools, multi-family homes, apartments, and high-rise buildings. These systems need to be balanced to ensure immediate and continuous availability of hot water at every fixture. People don’t want to wait minutes before their showers and faucets begin to heat up to a comfortable temperature. However, supplying hot water to every unit can be tricky for buildings that aren’t balanced correctly.

Balancing valveboiler

However, if you're unsure or uncomfortable with performing the repair yourself, it's always best to seek the assistance of a professional plumber to avoid any potential complications.

The fluid in these lines will migrate to the path of least resistance and starve the other loads from receiving the proper flow to offset the heat loss in their particular branch. To prevent this, the system needs to be “balanced.”

CircuitSolver® is a thermostatic balancing valve installed at the end of each hot water supply branch in a DHWS. Self-actuating, this valve automatically and continuously adjusts flow to maintain the specified temperature at the fixtures. When the specified water temperature is satisfied, the valve closes, allowing only a small flow bypass to the return line. This constant low flow rate prevents dead-heading the recirculation pump.

If you have a Febco 765 Pressure Vacuum Breaker (PVB) installed on your water supply system, you may encounter issues over time that require repair.

If you are not confident in your abilities, it's best to consult a professional plumber. Now, let's get started with the repair process

Balancing valvefor chilled water

Traditionally, this balancing has been done by flow devices such as manual balancing valves or constant flow valves. However, the problem with manually balancing a cooling water system is that it takes an unnecessarily long time and is not always accurate in dynamic systems with fluctuating pressures, wasting time and money in balancing procedures and equipment.

The TV/HAT-RA-LP works as an after-flow controller installed on the cooling water outlet of the equipment. The valve modulates open and closed to maintain a relatively constant outlet water temperature.

Before we begin, it's important to note that working with water supply systems requires a basic understanding of plumbing and some tools.

If you notice any debris, sediment, or mineral buildup inside the PVB, it's essential to clean it thoroughly. Use a mild detergent and a brush to scrub away any deposits. Rinse the components with clean water to ensure they are free from any residue.

Balancing Valveplumbing

It's also recommended to have a professional plumber perform an annual backflow preventer test to ensure the PVB is functioning correctly.

Begin by shutting off the main water supply to your property. This will prevent water from flowing through the PVB during the repair process.

Thermostatic balancing valves are a key component in many Commercial Plumbing/HVAC, Industrial, and Aerospace & Defense applications where many heating/cooling loads are being supplied by a single source of hot and/or cold water or other fluid. Although these loads all have the same temperature requirement, they are typically different distances away from the fluid source. This distance causes them to experience various heat losses as the fluid is pumped to their specific locations.

Balancing valvesymbol

Once all the components have been cleaned and inspected, carefully reassemble the PVB in the reverse order of disassembly. Make sure to tighten all screws or bolts securely but avoid over-tightening, as it may damage the PVB.

Check the O-rings and seals for signs of wear or damage. If necessary, replace these components with new ones from a Febco repair kit or contact the manufacturer for replacement parts. It's essential to use genuine parts to ensure the proper functioning of the PVB.

Remember, proper maintenance and regular inspections are key to keeping your PVB in optimal condition and ensuring the safety of your water supply system.

ThermOmegaTech® offers thermostatic balancing valves that automatically modulate and regulate flow through a system in response to temperature variations to provide precise and uniform temperatures to all branches. It is a temperature device solving a temperature problem.

The HAT/RA-LP can be used as a thermostatic balancing valve to dynamically regulate the cooling water, glycol, or other cooling media outlet temperature in these systems.

Thermal balancing is recommended for these types of systems not only because it evenly distributes hot water to every fixture but it is also one of the most reliable solutions for water hygiene. The valves automatically keep high-temperature water in the supply lines, which helps to protect against pathogen growth.

Automaticbalancing valve

Open a faucet located downstream of the PVB to relieve any remaining pressure in the system. This step is crucial to prevent any accidents or injuries.

The thermal actuator in the valves continuously senses the fluid temperature. As the temperature rises above the valve’s set-point, the valve will modulate open, allowing the cooling media to flow through it. When the desired fluid temperature is reached, the valve will modulate closed again. This process conserves water and improves the consistency of product quality.

Injection, rubber, and plastic molding equipment, die casting, and platen processes all require proper cooling to provide uniform temperatures and consistent product quality. Different types of cooling towers and systems can be used for these applications, many of which have multiple cooling loads or zones that need to be balanced.

Carefully inspect the poppet assembly for any signs of damage or debris that may be preventing it from functioning properly.

With the PVB reassembled, turn on the main water supply and check for any leaks or abnormal behavior. If everything looks good, open all faucets and let the water run for a few minutes to flush out any air or debris in the system.