Vent silencers must be designed to handle a variety of steam pressures with high velocity inlet flow. The silencers manufactured by SVI Bremco have three major components, an inlet radial diffuser, lower plenum section and an upper absorptive (passive) silencer. Let’s examine how these components work together to dampen noise.

Steam ventrice cooker

Safety vent silencers are an important component of steam generators. These components operate under high mechanical and thermal stress, and will fail without regular inspection and maintenance. A failure may raise noise to unacceptable levels. Furthermore, pieces of failed components may discharge from the vent to produce a safety hazard. SVI Bremco provides the services and equipment to protect and maintain these vital power plant items.

Power Engineering®️ is the voice of the power generation industry including news, exclusive articles, and in-depth reviews. Subscribe today to receive critical information and industry updates to remain competitive in today’s market.

Steam ventValve

2. Excessive Water-Induced Corrosion. To the greatest extent possible, silencers and their discharge vent should be designed to minimize water collection from rain and condensation. Given the cycling nature of combined cycle units, control of water accumulation can be a challenging task.

This stage helps to dissipate the incoming acoustic energy of the stream and splits the single stream into hundreds of smaller streams at each wall stage. This begins the noise attenuation process and decelerates the flow for further attenuation in the upper absorptive silencer.

b. Materials thickness and well-designed support components. Techniques such as computational fluid dynamics (CFD) can help determine the stresses on components and provide maximized structural design. CFD is also a critical technique in evaluating the aerodynamics of silencers and optimizing designs to reduce high steam velocity and back pressure.

Radiatorsteam venthissing

Steam ventmeaning

The lower plenum section serves as an expansion chamber for radial dispersion of the steam. This arrangement provides for uniform flow to the absorptive silencer upper stage.

SteamVents mtg

This is shown as the floating diffuser in Figure 1. The diffusers can be designed in a one-, two-, or three-wall arrangement based on system conditions. Each layer has a specifically-designed perforation pattern that allows the steam to expand through mesh material located between the wall stages and the core of the diffuser. The floating basket design allows for thermal expansion in both the axial and transverse directions.

3. Inspections. Silencers, like some other power plant components, often fit in the “out of sight, out of mind” category; that is until a major failure brings the equipment to everyone’s attention. The next section outlines important items for silencer inspections.

About the Author: Brad Buecker is president of Buecker & Associates, LLC, consulting and technical writing/marketing. Most recently he served as Senior Technical Publicist with ChemTreat, Inc. He has over four decades of experience in or supporting the power and industrial water treatment industries, much of it in steam generation chemistry, water treatment, air quality control, and results engineering positions with City Water, Light & Power (Springfield, Illinois) and Kansas City Power & Light Company’s (now Evergy) La Cygne, Kansas station. His work also included 11 years with two engineering firms, Burns & McDonnell and Kiewit, and he also spent two years as acting water/wastewater supervisor at a chemical plant. Buecker has a B.S. in chemistry from Iowa State University with additional course work in fluid mechanics, energy and materials balances, and advanced inorganic chemistry. He has authored or co-authored over 250 articles for various technical trade magazines and has written three books on power plant chemistry and air pollution control.  He may be reached at [email protected].

AdjustableSteamradiatorVent

These vents are located at or extend to the top of the unit for safety reasons. Even at a high elevation, when a safety valve lifts the noise can be intense. Accordingly, the vents on many HRSG units are equipped with vent silencers to dampen the noise. The basic diagram of a steam vent silencer (SVS) is shown in Figure 1.

a. Materials metallurgical composition. Higher grade alloys than plain carbon steel, although adding expense, may pay for themselves in increased durability.

c. Welding techniques. Proper welding techniques and selection of weld filler material are critical throughout steam generating systems including silencers. Welding induces localized stresses that can become rapid failure points if the welding is not planned and performed properly.

Safety vent silencers are an important component of steam generators and will fail without regular inspection and maintenance.

Combined-cycle power plants are frequently located in or near residential or commercial areas, with many people residing or working near the plant. The high energy required for power production generates much noise, which, without abatement controls, would be intolerable to the public and would present a safety hazard. One potential source of intense noise are the steam vents on heat recovery steam generators (HRSGs). Design, inspection and maintenance of steam vent silencers (SVS) are critical items of a plant’s noise abatement plan.

Steam ventoni

A recommendation at any industrial plant is to develop written protocols for every process and inspection, and to strictly follow the guidelines at all times. However, in this era of minimal staffing at many plants (combined cycle facilities are prime examples) plant personnel may not have the expertise to evaluate all situations. A solution is to work with an industry expert or company to develop inspection guidelines and perhaps assist directly with the inspections. The following lists outline primary inspection parameters for SVI silencers.

Image

Of course, thermal stress issues in combined cycle units and HRSGs are usually quite substantial because of the regular load cycling of most units. However, numerous proactive techniques are available to improve performance and longevity of silencers. Primary concepts include:

Steamvents geothermal

Image

As can readily be surmised, silencers, and especially the inlet radial diffuser, are subject to large mechanical and thermal stress. Material degradation over time is the result. SVI Bremco can, to some extent, proactively address these issues by replacing older pressure safety valves (PSV) with modern designs that reduce steam-flow mechanical stress on silencer components. Even so, wear and tear on silencer components is still of primary concern. The photos below illustrate several of the most important issues.

Image

Not only do these corrosion mechanisms affect silencer performance, but failed components can blow out of the silencer, presenting a potential safety hazard.