WARNING: The discharge from a T&P valve can be very hot. It is very important that all T&P valves be installed properly with a discharge line piped downward to an adequate drain to avoid property damage and to minimize possible human contact. Please read and follow the instructions on the warning tag attached to your T&P valve.

Your name Your email Subject Your message (optional) Troubleshooting Common Plumbing Issues A correctly designed and installed home plumbing system is practically trouble-free of most plumbing problems. But even the best systems can develop problems from time to time – everything from burst and leaking pipes to clogged drains. Here are some of the most […]

Your name Your email Subject Your message (optional) Next Plumbing in Fort Myers is known for two things: great plumbing services at great prices and caring for our community. In the spirit of supporting our friends and neighbors, we are teaming up with the Premier Zumba Team of Southwest Florida to bring the fight to breast cancer! We will be hosting […]

As with most homeowners, you probably only think about your water heater when there is no hot water for your shower or you notice a puddle underneath the water heater. Whatever the reason, when it is time to buy a water heater, consider electric ones because they offer features that ensure a long life and an economical supply of hot water.

The 1" Watts Series 009 Reduced Pressure Zone Assemblies are Watts "contractor grade" RPZ device. They were in production from 1989-1992. The original 1" 009 was replaced by the 009M2 in 1992. The 009 features a one cover design and is constructed of bronze and use check modules that slide into the body and are held in place with a retainer. The relief valve assembly slides down between the retainer and is directly under the cover. The check modules and relief valve assembly come apart for service. The original 009s parts do not interchange with the "M" models, so please be sure which model you have before ordering. No special tools are required for servicing 009 Series devices. Maintenance ManualSpecification Sheet

Important: A relief valve functions, in an emergency, by discharging water. Therefore it is essential that a discharge line be piped from the valve in order to carry the overflow to a safe place of disposal. The discharge line must be the same size as the valve outlet and must pitch downward from the valve.

Also, be sure to compare federal Energy guide labels on electric water heaters before you choose one. The Energy guide label will give you the unit’s estimated annual energy cost. A high-efficiency electric water heater costs more than an inefficient one, but you will be paid back through lower electric bills.

Now that you know what it looks like, and what it does, take the time to check it and make sure yours IS NOT CAPPED OR PLUGGED and that it works properly. You can lift the little handle on it like the picture shows. Sometimes you may need to let the handle snap back down to reseat it properly. If it continues to leak a little, it either has some debris in it or the spring is failing. You can try and open it a few times to remove any debris. If this does not take care of it, call a plumber and have it replaced. Make sure there is a relief tube extending to the floor in case the heater must discharge. This is to prevent accidental scalding. Also, you should not have threads on the bottom of the relief tube. This will ensure that a cap cannot be screwed onto the bottom.

In doing so, a small amount of water will also be dispensed onto the floor. Unfortunately, many people mistake this for a leak or a water heater failure, when in fact, it may simply be doing what it is designed to do. If you ever see water on your floor around this area, you should call a plumber right away. The valve may be failing, in which case it should be replaced, or you may have excessive pressure in your tank, which should be tested for.

One great feature of many types of electric water heaters is a non-metallic storage tank. Manufacturers of these tanks warranty them against leakage, eliminating a major cause of early water-heater failure. And if you live in an area with corrosive water, you’ll find this feature to be especially cost-effective.

Important Instructions: Relief Valves and Automatic Gas Shut-Off Devices Combination temperature and pressure relief valves with extension thermostats must be installed so that the temperature-sensing element is immersed in the water within the top 6″ (152mm) of the water storage tank. They must be installed either in the hot outlet service line or directly in a tank tapping. Combination temperature and pressure relief valves that do not have extension elements must be mounted directly in a tank tapping located within the top 6″ (152mm) of the water storage tank. Valves must be located so as to assure isolation from flue gas heat or other ambient conditions that are not indicative of stored water temperature.

Less water is wasted going down the drain while you wait for it to get hot, and less energy is wasted heating water that ends up in the pipeline between a faucet and a distant water heater.Overall, an energy-efficient electric water heater is the long-term smart choice for clean, quiet and economical hot water.

Do not attempt to conduct an inspection on your own. Contact your plumbing contractor for a re-inspection to assure continuing safety. FAILURE TO REINSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH CAN RESULT IN SERIOUS INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE.

Certain naturally occurring conditions may corrode the valve or its components over time, rendering the valve inoperative. Such conditions can only be detected if the valve and its components are physically removed and inspected.

Image

No shut-off valve shall be installed between the relief valve and tank, or in the discharge line. Valve lever must be tripped at least once a year to ensure that waterways are clear. When manually operating lever, water will discharge through discharge line and precautions must be taken to avoid contact with hot water and to avoid water damage. This device is designed for emergency safety relief and shall not be used as an operating control. If discharge occurs, a licensed contractor must evaluate the system and determine the cause for discharge and correct the cause immediately.

To ensure proper operation, this valve must be installed by a qualified service technician or licensed plumbing contractor in accordance with these instructions and the local plumbing codes and standards. Repair or alteration of valve in any way is prohibited by national safety standards/local codes.

If you happen to have a pressure reducing valve installed on your main water line, you should pay special attention to this. A pressure reducing valve creates a closed system in your home, and will not allow for thermal expansion. If you have one of these, AND your T&P valve drips occasionally, you may need a thermal expansion tank installed.

The T&P valve, or temperature and pressure relief valve, is one of the most important safety devices in your home. If the temperature rises above 210 degrees Fahrenheit or the pressure exceeds 150 psi, the valve will open and relieve the pressure inside the tank.

Image

Caution: Valve must be installed so that temperature sensing element is immersed in the water within the top 6″ (152mm) of the tank.No valve may be placed between the relief valve and water tank.Install in hot water outlet or in extra side relief valve tapping if one is provided.To avoid water damage, discharge line must be run to a safe place of disposal and must pitch downward.Do not install a shut-off valve, plug, or cap in the valve discharge line.Follow local codes where they vary from these instructions.

Use standard or extra length extension thermostat which permits the end of the thermostat to extend into the top 6″ of the tank.

Temperature and pressure (T&P) relief valves used on residential water heaters are typically designed and manufactured to relieve on pressure at 150 psig and on temperature at 210 degrees F. These ASME, ANSI and CSA (AGA) approved relief valves protect the water heater from excess pressures and temperatures by discharging water.

WARNING: Temperature and Pressure Relief Valves should be inspected AT LEAST ONCE EVERY THREE YEARS, and replaced, if necessary, by a licensed plumbing contractor or qualified service technician, to ensure that the product has not been affected by corrosive water conditions and to ensure that the valve and discharge line have not been altered or tampered with illegally.

If installation of a thermal expansion device does not relieve occasional dripping from the T&P valve, then the system pressure should be checked. If system pressure is excessive (typically more than 75 PSI), a Watts pressure regulator should be installed on the incoming water line.

Image

If discharge occurs, CALL A PLUMBER IMMEDIATELY. Discharge may indicate that an unsafe temperature or pressure condition exists which requires immediate attention by a qualified service technician or licensed plumbing contractor.

Recently, I came across a very dangerous situation with electric water heaters, one that Next Plumbing thinks needs to be addressed. A capped or plugged water heater T&P valve is one of the worst “band-aid” fixes you could ever do in your house. Doing so creates the grounds for a potential bomb or missile in your basement! Although rare, the threat of a water heater explosion is very real. It is crucial to hire an experienced and licensed plumber to fix your water heater instead of using DIY “band-aid” fixes.

In normal operation of the water heater and T&P valve, no water should be discharged from the valve. A T&P valve that discharges is an indication of an abnormal condition in the system and by discharging, the T&P valve is meeting its designed safety purpose. The causes of discharge can be thermal expansion, excess system pressure, low temperature relief, too high a setting on the water heater, or something in the water heater causing excess temperatures in the heater.

When water is heated it expands. In a 40 gallon water heater, water being heated to its thermostat setting will end up expanding by approximately 1/2 gallon. The extra volume created by this expansion has to go somewhere or pressure will dramatically increase, such as when water is heated in a closed system.

WARNING: To avoid water damage or scalding due to valve operation, discharge line must be connected to valve outlet and run to a safe place of disposal. Discharge line must be as short as possible and be the same size as the valve discharge connection throughout its entire length. Discharge line must pitch downward from the valve and terminate at least 6″ (152mm) above a drain where any discharge will be clearly visible. The discharge line shall terminate plain, not threaded. Discharge line material must conform to local plumbing codes or ASME requirements. Excessive length over 30′ (9.14m), or use of more than four elbows or reducing discharge line size will cause a restriction and reduce the discharge capacity of the valve.

Another factor to look for when you’re shopping for a new electric water heater is the amount of built-in insulation it offers. Although this type of water heater generally costs more than one with minimal insulation, you’ll be saving money in the long run by reducing the amount of electricity needed to keep the water hot.

Electric water heaters come in a variety of shapes and sizes, and unlike a gas water heater, you don’t have to install gas pipelines or flues. An electric water heater, therefore, can be installed closer to the rooms that use hot water.

Controlling your water heater allows you to take full advantage of the efficiency of the storage tank. This allows water to be heated during non-peak hours for use throughout the day. Automatic timers can do the job for you. Properly sized water heaters provide enough hot water to meet your needs round the clock.

Always use an extension type thermostat T&P relief valve which permits the end of the thermostat to extend into the top 6″ of the tank.

A good indication of thermal expansion is when the T&P valve releases about one cup of water for each 10 gallons of heater capacity with each heating cycle. The T&P valve is functioning properly when it relieves pressure caused by thermal expansion, but frequent relief can build up natural mineral deposits on the valve seat, rendering the valve inoperative. This condition can be addressed by the installation of a Watts thermal expansion tank or other Watts thermal expansion device to protect your system from overpressure caused by thermal expansion. If there is no discharge from the valve, there is no need to replace the valve.

WARNING: Following installation, the valve lever MUST be operated AT LEAST ONCE A YEAR by the water heater owner to ensure that waterways are clear. Certain naturally occurring mineral deposits may adhere to the valve, blocking waterways, rendering it inoperative. When the lever is operated, hot water will discharge if the waterways are clear. PRECAUTIONS MUST BE TAKEN TO AVOID PERSONAL INJURY FROM CONTACT WITH HOT WATER AND TO AVOID PROPERTY DAMAGE. Before operating lever, check to see that a discharge line is connected to this valve, directing the flow of hot water from the valve to a proper place of disposal. If no water flows when the lever is operated, replacement of the valve is required. TURN THE WATER HEATER “OFF” (see your water heater instruction manual) AND CALL A PLUMBER IMMEDIATELY.