How Radiant Floor Heating Works - how long does radiant heat take to warm up
LF800M4QT
Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.
The mini dual check valves are primarily designed to provide protection from potential contamination to the potable water supply in low hazard applications for individual fixtures.
Watts 800M4FR
Vacuum Breaker, Anti-Siphon, FIP Connection, 1 inch Connection, O-Ring Seal, 150 psi Max. Pressure, Temperature Range: 33 To 140 Deg F, Stainless Steel Springs, Celcon Bonnet, Silicone Rubber Vent Disc, Polypropylene Disc Holder Float, Silicone Rubber Check Valve Disc, Noryl Plastic Check Valve Seat, Bronze Body, 7-1/2 inch Height, Standards: ASSE Standard 1011, C/US CSA Certified, ISO 9001-2000 Certified, UPC Listed, ANSI, USC
We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.
800M4QTRepair Kit
Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.
800M4QT1
Series 800M4QT Anti-Siphon Pressure Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage. It consists of bronze body construction, silicone rubber check valve disc, plastic check valve seat, stainless steel springs, a bonnet with silicone rubber O-ring seal, a lightweight plastic disc float, tee handle or lever handle shutoffs, and test cocks for winterization draining. Series 800M4QT is ideal in health hazard continuous pressure applications such as irrigation systems and industrial process water systems where the water enters the equipment at or below its flood rim.
The mini dual check valves are primarily designed to provide protection from potential contamination to the potable water supply in low hazard applications for individual fixtures.
watts800m4qt3/4
Our range of backflow prevention devices are manufactured in our WA factory and approved to AS/NZS 2845.1. Constructed from dezincification resistant (DR) brass the units consist of two independently acting internally loaded check valves. With a low hazard rating the units perform to a maximum temperature of 60 degrees celsius and a maximum pressure of 1200kPa. All units can be installed vertically or horizontally however they must not be subject to flooding or freezing.
While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.
Our range of backflow prevention devices are manufactured in our WA factory and approved to AS/NZS 2845.1. Constructed from dezincification resistant (DR) brass the units consist of two independently acting internally loaded check valves. With a low hazard rating the units perform to a maximum temperature of 60 degrees celsius and a maximum pressure of 1200kPa. All units can be installed vertically or horizontally however they must not be subject to flooding or freezing.