RADIANT FLOOR HYDRONIC (water) HEATING SYSTEM - hydronic radiant floor heating
21/2backflow preventer
Manufactured by Bailey Birkett, the G4 series of pilot operated pressure reducing valves provide extremely accurate levels of pressure regulation for steam, air and industrial gas applications. The valve relies upon a stable pressure signal from the outlet pipework in order to maintain stable control of the outlet pressure. Type Pilot Operated Size & Connections DN15 to DN50 • PN40 Flanged (PN16/25, ANSI 150/300 & BST F/H on request) Duty Air • Gases • Steam Materials Bronze Body • Stainless Steel Trim* Upstream Pressure Range 0.7 to 35 Bar (dependent on duty) Downstream Pressure Range 0.07 to 21 Bar Temperature -20°C to 260°C (dependent on trim, see datasheet for details) Spares Routine & Full Repair Kits Available – Available in our webshop * Option of PTFE • Nitrile (31 bar max) • FKM (31 bar max)
Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists.
2Double Check ValveBackflow Preventer
Manufactured by Spirax Sarco, the BRV2S is a direct-acting pressure valve for use on steam, compressed air and other gases. The compact design makes it ideal for point of use installations, providing accurate control of pressure under stable load conditions. Type Direct-Acting Size & Connections 15mm (1/2″) to 25mm (1″) • BSP Female (NPT & Flanged PN25 on request) Duty Air • Gases • Steam Materials SG Iron Body • Bronze or Stainless Steel Bellows • Stainless Steel Valve Seat Maximum Upstream Pressure Up to 19 Bar Downstream Pressure Range 0.35 to 8.6 Bar Temperature 0°C to 210°C
JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
2 backflow PreventerPVC
You can quickly connect your existing business account for a simplified shopping experience. Receive all the benefits of a Retail Account plus custom pricing, real-time inventory, access to special promotions, pay your bills online, quick order, and more.
backflowpreventer中文
2 Backflow PreventerWatts
Home | Quality & Environmental Policy | Accreditation | Terms & Conditions | Sitemap | Contact | About Us | My Account | Basket | Shop
2rpzBackflow Preventer
We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more
Creating a Retail Account has many benefits: faster checkout, save multiple addresses, track orders, create wish lists, and more.
An economical alternative option for the Spirax Sarco BRV, it’s a compact direct-acting pressure reducing valve which is suitable for steam, air and neutral gases. Type Direct-Acting Size & Connections 15mm (1/2″) to 25mm (1″) • BSP Female Duty Air • Neutral Gases • Steam Materials Ductile Iron Body • Stainless Steel Bellows, Valve, Seat & Spring Maximum Upstream Pressure 17 Bar Downstream Pressure Range 0.14 to 8.6 Bar Temperature 0°C to 210°C Compliance & Approvals 3.1 Material Cert (on request)
Manufactured by Bailey Birkett, the G4 series of pilot operated pressure reducing valves provide extremely accurate levels of pressure regulation for steam, air and industrial gas applications. The valve relies upon a stable pressure signal from the outlet pipework in order to maintain stable control of the outlet pressure. Type Pilot Operated Size & Connections 15mm (1/2″) to 50mm (2″) • BSP Female Duty Air • Gases • Steam Materials Bronze Body • Stainless Steel Trim* Upstream Pressure Range 0.7 to 35 Bar (dependent on duty) Downstream Pressure Range 0.07 to 21 Bar Temperature -20°C to 260°C (dependent on trim, see datasheet for details) Spares Routine & Full Repair Kits Available – Available in our webshop * Option of PTFE • Nitrile (31 bar max) • FKM (31 bar max)
Manufactured by Bailey Birkett, the G4 series of pilot operated pressure reducing valves provide extremely accurate levels of pressure regulation for steam, air and industrial gas applications. The valve relies upon a stable pressure signal from the outlet pipework in order to maintain stable control of the outlet pressure. Type Pilot Operated Size & Connections DN65 to DN100 • PN16 Flanged (ANSI 150/300 & BST F/H on request) Duty Air • Gases • Steam Materials Carbon Steel Body • Stainless Steel Trim* Upstream Pressure Range 0.7 to 35 Bar (dependent on duty) Downstream Pressure Range 0.07 to 21 Bar Temperature -20°C to 260°C (170°C for PTFE trim) * Option of PTFE
Manufactured by Bailey Birkett, the G4 series of pilot operated pressure reducing valves provide extremely accurate levels of pressure regulation for steam, air and industrial gas applications. The valve relies upon a stable pressure signal from the outlet pipework in order to maintain stable control of the outlet pressure. Type Pilot Operated Size & Connections DN15 to DN100 • PN40 Flanged (PN16/25, ANSI 150/300 & BST F/H on request) Duty Air • Gases • Steam Materials Carbon Steel Body • Stainless Steel Trim* Upstream Pressure Range 0.7 to 42 Bar (dependent on duty) Downstream Pressure Range 0.07 to 21 Bar Temperature -20°C to 400°C (dependent on trim, see datasheet for details) * Option of PTFE • Nitrile (31 bar max) • FKM (31 bar max)
Manufactured by Bailey Birkett, the G4 series of pilot operated pressure reducing valves provide extremely accurate levels of pressure regulation for steam, air and industrial gas applications. The valve relies upon a stable pressure signal from the outlet pipework in order to maintain stable control of the outlet pressure. Type Pilot Operated Size & Connections DN65 to DN100 • PN16 Flanged (ANSI 150/300 & BST F/H on request) Duty Air • Gases • Steam Materials Carbon Steel Body • Stainless Steel Trim* Upstream Pressure Range 0.7 to 16 Bar (dependent on duty) Downstream Pressure Range 0.07 to 15 Bar Temperature -20°C to 220°C (170°C for PTFE trim) Spares Routine & Full Repair Kits Available – Available in our webshop * Option of PTFE