I will go ahead and state my opinion from the outset: I don’t believe one should ever use these diabolical and deceptive fittings, under any circumstance.

Image

I know this is all anecdotal evidence, but it is an opinion that is shared by virtually every experienced plumber I’ve spoken to, which adds up to hundreds of years of collective experience.

his was the basis of all modern wet-cell batteries, and it was the first method found for the generation of a sustained electrical current.

19 Dec 2023 — In addition to digital alerts, leak defense systems may include audible alarms within the home or building. These alarms provide an immediate, ...

The piggy-back funnel drain is the funnel and drain assembled as a complete unit. Manufactured and assembled in the USA by Plastic Oddities.

In these situations we have all three elements required to foster galvanic corrosion, two metals with different corrosion potentials, copper (cathode) versus steel (anode), direct contact between them as they are being connected, and the presence of a corrosive electrolyte being the water.

The valve maintains the temperature to within +/- 3 degrees through both high and low demands. ... NRS-4, 1.5 (5.5), 12.5 (58.0), 19.0 (89.0), 24.0 (115.0) ...

202499 — Water quality and health. Responsibility for drinking water safety in Canada, drinking water contaminants, recreational and drinking water ...

Preventing galvanic corrosion depends on removing one of these three elements. Dielectric unions have rubber gaskets and plastic sleeves that are intended to act as insulators which separate and break the electrical continuity between the two metals by removing the element of direct contact between the two metals.

I also read the results of a study in 2013 done by Penn State University, Office of Physical Plant, Energy and Engineering Division, Engineering Services, which observed:

374E

The purpose of this part is to issue rules pursuant to the Federal Election Campaign Act of 1971, as amended, in accordance with the Department's responsibility thereunder.

Common examples of connections of dissimilar metals would include copper water lines connecting to old galvanized steel lines, or copper water lines connecting to a steel hot water tank.

“…My own home has some brass to galvanized steel connections in the basement that I meant to change out years ago, but they are holding fine and give no sign of trouble. The connections are probably 75 years old. I’ve seen dielectric unions fail within five years.”

Our industry has used this process in beneficial ways also, the most obvious example is the use of magnesium, zinc or aluminum in the form of sacrificial anode rods to protect steel hot water tanks from corrosion.

Image

Now that we have (hopefully) a better understanding of the science involved, let’s go back to the argument of whether or not dielectric unions are an effective way to connect dissimilar metals in a plumbing system.

When these bimetallic couples form, one of the metals corrodes faster than it would all by itself, while the other corrodes slower than it would alone, or not at all. The metal that corrodes during galvanic corrosion is known as the anode, and the metal that doesn’t corrode is known as the cathode. Metals that are more cathodic are referred to as more noble metals. (See anodic chart)

Not only do they not work, but they actually seem to make the problem worse. I am not alone in my opinion. Do a Google search and you will find countless plumbers with many years of experience posting the same opinion.

道路 交通 车辆 构造 及 保养 规 例

2019812 — You would need a 2 1/2 gallon .that's from a real plumber who works on broilers and tons of water heaters.take care

Tekmar Control Systems. TSTAT/CTRL/SLAB SENSOR/10K OHM. 4 in stock. $69.68. ADD TO CART. TEKMAR316. Tekmar Control Systems. EXPANSION MODULE. Lead time ...

Sometimes you won’t have any choice because a smarter-than-all-of-us engineer or inspector may insist on the diabolical dielectric, but when the choice is yours go with the brass, and in the words of Julian of Norwich, “All will be well, and all will be well and every kind of thing shall be well.” <>

In the case of plumbing and heating systems the electrolyte is the water in the system. The contacting metals form a bimetallic couple because of their different affinities (or attraction) for electrons. These different affinities create an electrical potential between the two metals, allowing a slight direct current to flow.

Julian of Norwich in her day wrestled with timeless theological issues with eternal implications, and today I want to wrestle with the age old and contentious question of when, if ever, one should use a dielectric union when joining two dissimilar metals.

Now before someone goes and accuses me of being a galvanic corrosion denier let’s look at what the science has to say. Galvanic corrosion, also know as “dissimilar metal corrosion” refers to corrosion occurring when two dissimilar metals come into contact with one another and simultaneously with a corrosive electrolyte.

Image

“…I am a licensed plumber for 20-plus years. When I started, it was code to install dielectric unions everywhere in houses where copper connects to steel. Every single union fails miserably by either leaking, clogging up completely, rusting to pieces”

This process was discovered in the late part of the eighteenth century by Luigi Galvani in a series of experiments with the exposed muscles and nerves of a frog that contracted when connected to a bimetallic conductor. In the early 1800’s the discovery was put into a practical application by Alessandro Volta who used a series of dissimilar metal disks, separated by cardboard soaked with acid or saltwater solutions to build the world’s first electrical cells, or batteries.

201935 — The 360 will not command the mixing valve to open until the boiler supply is registering (close to) 180degF.

I’ve merely spent a few weeks in semi-seclusion; I’ve managed to survive the Covid-19 pandemic, so far at least; and I’m struggling to write a few simple paragraphs of simple plumbing prose, hopefully they will survive till the next recycling run, so here goes.

If your property is assessed as a High or Medium hazard risk, then you need to install an appropriate containment backflow prevention device.

Julian of Norwich spent much of her life living in seclusion; she survived the Black Death, and she managed to write the earliest surviving book written in the English language by a woman.

Yes, I am aware that many codes require them, many engineers specify them and many inspectors want to see them. Still, I will stand firm in my assertion that these fittings have no place in any plumbing or heating system.

In my experience, a 6-inch long brass nipple directly connected to the hot water tank or brass unions or couplings will yield much better and longer lasting corrosion free results than any dielectric union ever will.

Thai AirAsia flight FD 323 Bangkok - George Town (DMK-PEN), duration 1h 45m, departure 10:50, Don Mueang Terminal 1, arrival 13:35, Penang.

374B

I freely admit that it may seem odd to lead off a plumbing article by quoting a 14th century mystic, but we are living in strange and uncertain times.

“Whenever a ferrous metal such as black steel is connected to a non-ferrous metal such as copper, a dielectric connection must be installed to prevent galvanic corrosion. The installation of a fitting with inert material between the two metals prevents the flow of electrons between the metals, preventing premature failure of the piping. Traditionally, dielectric unions have been installed to perform this function. However, dielectric unions are proven sources of leaking fittings, and should be avoided.”

Buy 256 256 Tekmar 1 Stage Boiler Reset Control from Building HVAC.